01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EPONA SA 220

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial gear oil

Manufacturers & Suppliers

T

TotalEnergies Lubrifiants

manufacturer

562 Avenue du Parc de L'ile, 92029 Nanterre Cedex FRANCE

+33 (0)1 41 35 40 00

T

TotalEnergies Marketing Services

national supplier

Direction Afrique, 24 cours Michelet, 92800 PUTEAUX, FRANCE

+33 (0)1 41 35 40 00

Emergency Contacts

Emergency Contact

+44 1235 239671

Emergency Contact

+44 1235 239670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Precautionary Statements

Not applicable.
Not applicable.
Not applicable.
Not applicable.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Amines, C10-14-tert-alkyl --- 0.3% No
C16-18-(even numbered, saturated and unsaturated)-alkylamines 1213789-63-9 0.1% No

The product is made from synthetic base oils

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if without risk. Move containers from spill area. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant.

Materials: inert dry material, sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Hydrocarbon-proof gloves Fluorinated rubber nitrile rubber Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

None under normal use conditions. If these are not sufficient to maintain exposure below the OEL, suitable respiratory protection must be worn.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
Not applicable.
Physical State Data
liquid
Vapor Pressure
<0.013 kPa (<0.1 mm Hg)
Softening Point
---
Solubility In Fat
---
Solubility In Water
Not soluble
Appearance
Liquid. [limpid]
Odor
Characteristic.
Crystallisation Point
---
Density
0.851 g/cm³ [15°C]
Properties Status
---
Colour Intensity
---
Lower Explosive Limit
0.9%
Voc Content
---
Molecular Weight
---
Melting Point
Technically not possible to measure
Odor Threshold
Not available.
Flash Point
242°C (467.6°F)
Colour
Yellow.to Amber.
Form
limpid
Evaporation Rate
Not available.
Cloud Point
---
Bulk Density
---
Freezing Point
-45°C (-49°F)
Explosive Limits
---
Vapor Density
>2 [Air = 1]
State Under Standard Conditions
---
Relative Evaporation Rate
---
Kinematic Viscosity
211 mm²/s (211 cSt)
Partition Coefficient
Not applicable.
Solubility
water: Not soluble. Miscible with water: No.
Upper Explosive Limit
7%
Physical State
Liquid.
Relative Density
0.851
Solidification Point
---
Auto Ignition Temperature
>242°C (>467.6°F)
Ph
Not applicable.
Boiling Point
>316°C (>600.8°F)
Decomposition Temperature
Not applicable.
Metal Corrosion
---
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Incompatible

Strong oxidizing agents

Decomposition

carbon monoxide, carbon dioxide, Silicon Dioxide, nitrogen oxides, phosphorus oxides, sulfur oxides, Hydrogen sulfide, Mercaptans

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EPONA SA 220?

The signal word is no signal word.

What is the physical form of EPONA SA 220?

EPONA SA 220 is a liquid. appearing as liquid. [limpid] with yellow.to amber. color. It has characteristic. odor.

What is the solubility of EPONA SA 220?

water: Not soluble. Miscible with water: No.

What is EPONA SA 220 used for?

Industrial gear oil

What are the hazard statements for EPONA SA 220?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of EPONA SA 220?