NextSDS Logo
Safety Data Sheet EN

AZOLLA ZS 22

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AZOLLA ZS 22

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cutting fluid, Hydraulic oil, neat metalworking oil

Manufacturers & Suppliers

T

TotalEnergies Lubrifiants

manufacturer

562 Avenue du Parc de L'ile, 92029 Nanterre Cedex FRANCE

+33 (0)1 41 35 40 00

T

TotalEnergies Marketing Belgium

distributor

Anspachlaan 1, bus 2 / Boulevard anspach 1, boîte 2, 1000 Brussel/Bruxelles – België/Belgique

+32 (0)22 889 933

T

TotalEnergies Marketing Belgium

+44 1235239670

Emergency Contacts

National advisory body/Poison Center

+32 70 245 245

SOS TotalEnergies Marketing Belgium (transport)

+32 78 15 51 51

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mineral oil of petroleum origin. Product containing mineral oil with less than 3% DMSO extract as measured by IP 346

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 50 - 75% No
Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 64742-55-8 25 - 50% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Skin contact

Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: irritation, dryness, cracking

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Ingestion

Wash out mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically. No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material.

Small spill

Stop leak if without risk. Move containers from spill area. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Contain and collect spillage with non-combustible, absorbent material and place in container for disposal according to local regulations.

Materials: sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Hydrocarbon-proof gloves nitrile rubber Fluorinated rubber Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. In case of prolonged contact with the product, it is recommended to wear gloves complying with ISO 21420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0,38 mm at least. These values are indicative only. The level of protection is provided by the material of the glove, its technical characteristics, its resistance to the chemicals to be handled, the appropriateness of its use and its replacement frequency

Eyes

In case of contact through splashing: safety glasses with side-shields, EN 166.

Respiratory

None under normal use conditions. If these are not sufficient to maintain exposure below the OEL, suitable respiratory protection must be worn (Type A/P1).

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Non-skid safety shoes or boots

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Colour
Yellow.
Molecular Weight
---
Relative Evaporation Rate
---
Upper Explosive Limit
Upper: 7%
Voc Content
---
Decomposition Temperature
Not applicable.
Solidification Point
---
Solubility
---
Softening Point
---
Partition Coefficient
Not applicable.
Dynamic Viscosity
Dynamic (room temperature): Not available.
Properties Status
---
Vapor Pressure
<0.013 kPa [room temperature]
Odor Threshold
---
Kinematic Viscosity
Kinematic (40°C): 20.6 to 24.2 mm²/s [ISO 3104]
Colour Intensity
---
Crystallisation Point
---
Physical State
Liquid.
Appearance
Liquid. [limpid]
Flammability
Not applicable.
Form
---
Ph
Not applicable.
State Under Standard Conditions
---
Odor
Characteristic.
Flash Point
Open cup: ≥200°C [Cleveland Open Cup (COC)]
Boiling Point
>316°C [ISO 3405]
Bulk Density
---
Evaporation Rate
---
Vapor Density
>2 [Air = 1]
Melting Point
Technically not possible to measure
Auto Ignition Temperature
>200°C [ASTM E 659]
Metal Corrosion
---
Density
0.856 to 0.866 g/cm³ [15°C] [ISO 12185]
Cloud Point
---
Physical State Data
liquid
Freezing Point
---
Lower Explosive Limit
Lower: 0.9%
Relative Density
0.856 to 0.866 [ISO 12185]
Solubility In Fat
---
Solubility In Water
Not soluble
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

Strong oxidizing agents

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AZOLLA ZS 22?

The signal word is no signal word.

What is the physical form of AZOLLA ZS 22?

AZOLLA ZS 22 is a liquid. appearing as liquid. [limpid] with yellow. color. It has characteristic. odor.

What is AZOLLA ZS 22 used for?

Cutting fluid, Hydraulic oil, neat metalworking oil

What is the melting point of AZOLLA ZS 22?

The melting point is Technically not possible to measure and the boiling point is >316°C [ISO 3405].