Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- EXAL 845
- Chemical Name
- glycerides unsaturated
Regulatory Identifiers
- CAS Number
- 67701-30-8 Check regulations →
- EC Number
- 266-948-4 Check regulations →
- REACH No.
- Free of registration by annex V (9).
Identified Uses
The product is registered for all technical/factual relevant uses of the Process category application techniques or process types (PROC), Chemical product category (PC), Sector of use category (SU), Environmental release category (ERC) and Article category (AC). (More information by special request.)
Uses advised against
No uses in the case of compliance with the conditions, described in this Material Safety Data Sheet.
Manufacturers & Suppliers
Schröder KG, Schmierstofftechnik
manufacturer
Am Hausplatz 7, D-57258 Freudenberg, Germany
++49 2734 7071
Emergency Contacts
Schröder KG
++49 2734 7071
Giftnotrufzentrale Berlin
++49 30 19240
24/24 h
Guy's & Thomas' Poisons Unit
++44 0870 243 2241
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
tztransformed vegetable oil, propan-1,2,3-triester mainly of octadecen acid (Oleic acid)
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| glycerides unsaturated EC: 266-948-4 | 67701-30-8 | --- | No |
3.2 Mixtures | Not applicable, substance.
First Aid Measures
Emergency procedures for chemical exposure incidents
Not relevant.
Symptoms: Not relevant.
Wash thoroughly with water and soap.
Rinse out eye with a soft cloth, if necessary use water or eye shower. Consult ophthalmologist if irritation persists.
Symptoms: Seldom delayed eye irritation possible (foreign body sensation).
Only in case of very big amounts: Do not induce vomiting. Rinse out mouth with plenty of water and drink amply water (two dinking glasses). In the case of feeling unwell consult medical service.
Medical Treatment
Symptomatic treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Oil resistant foam (AFFF), extinguish powder (BC) for flammable liquids, powder or liquid carbon dioxide (CO2)-fire-extinguisher, water spray.
Solid water jet, liquid burning product may be dispersed.
Dust/smog or combustion gases are heavier-than-air and may be concentrated on bottom, in trenches, canals, drains or cellars.
The fire fighting measures necessary have to be co-ordinated with the local administration and adapted to the environmental conditions. Use water spray to protect persons and to cool tanks, vessels or other reservoirs in the range of dangers.
Firefighter Protection
Personal protective suit and protective breathing apparatus (independent form ambient atmosphere). Do not breath explosion gases or/and fire gases.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep off the range of dangers and inform trained emergency personnel. Do not take any personal risk. Do not breathe vapour/aerosols. Avoid contact to skin and eyes. Attend emergency plan! Activate information chain and follow it.
Inform immediately administration/ fire brigade/police if in bigger amounts the product infiltrated a sewage system or a water body.
Pick up spilled material dry. Avoid infiltration of product into sewage systems/water bodies/ground earth.
Pick up spilled material dry.
Materials: industrial cleaner for oil/fat
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use personal protection equipment. (See also section 8.)
The product reacts slowly with air (partial vacuum can be generated). Hold containment tight closed. Storage dry at a well ventilated place. Optimal temperature for storage: solid 5 to 25 °C, liquid at melting point.
Realise access only for authorised persons. Avoid contact to skin and eyes. Separate strictly area for working and for non-working time. Observe continuously labelling regulations. Realise good ventilation in the working area. Make sure, that every time the cleaning of the working area is possible.
Keep off hot liquid or sprayed product from heat or ignition sources, realise measure against electrostatic charge, avoid concentration of dust/vapour in the air. (See also section 5.)
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Usable technical handling equipment and control unit have to be designed in such a way, that it is avoided widely the contact of workers (respiratory tract, eyes, skin) to the product and there is no trapping hazard by vapour-air-mixes, electrostatic charge and other ignition sources. (See also Article 4-6 of Directive 98/24/EC, Article 3-5 of Directive 2004/37/EC). Technical protection measures take priority over individual protection measures.
Prevent protection by skin cream, protection gloves (or gauntlets if necessary, material: nitrile, chloroprene or fluoro rubber, 0.11 mm, breakthrough time > 8 h. Make leak test before use.
Use safety goggles with side protection or face protection shield (safety glass or polycarbonate).
Can be potentially necessary in case of generation of dust/vapour. For average pollution use filters for organic gases and vapours (type A). In case of higher concentration of product in the air (e.g. fire) use protective breathing apparatus (independent form ambient atmosphere). Take time limits for the users into account.
The normal working clothes have to be adapted to the workplace and the related hazards (e.g. flame retardant suit, chemical resistant suit, antistatic protection suit). Change immediately contaminated clothing. Put on anti-slip and antistatic protection shoes/boots.
Do not release material into environment. Avoid environmental exposure by technical und organisational measures.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is physical and chemical stable under normal environment conditions (storage temperature).
Stable under normal environment conditions
In the case of fine dispersion (dust/vapour), big surface, strong heating (naked flame, strong UV-/sun radiation), oxygen (air, wind) ignition or auto-ignition is possible.
fine dispersion (dust/vapour), big surface, strong heating (naked flame, strong UV-/sun radiation), oxygen (air, wind)
strong oxidising agents
Normal situation: no. In case of fire: carbon dioxide and water; Carbon monoxide, carbon black, product dust/smog and partly burnt hydrocarbons. Dust/smog or combustion gases are heavier-than-air and may be concentrated on bottom, in trenches, canals, drains or cellars.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for EXAL 845?
The signal word is no signal word.
What is the physical form of EXAL 845?
EXAL 845 is a liquid appearing as light yellow, clear with light yellow, clear color. It has characteristic, reminds of vegetable oil odor.
What is EXAL 845 used for?
The product is registered for all technical/factual relevant uses of the Process category application techniques or process types (PROC), Chemical product category (PC), Sector of use category (SU), Environmental release category (ERC) and Article category (AC). (More information by special request.)
What is the melting point of EXAL 845?
The melting point is maximal -6, depends on basic material °C and the boiling point is > 170, smoke point 150, >200 decomposition DIN EN ISO 3405 °C.