NextSDS Logo
Safety Data Sheet EN

Promag RI & PR-I & PI

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Promag RI & PR-I & PI
Product Form
granular / fines <1mm
Product Code
07017 - PRI
Synonyms
Pyromag RI

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Flux used to remove sodium, calcium and lithium from wrought aluminum alloys.

Uses advised against

Not fit for use in anything related to human consumption.

Manufacturers & Suppliers

P

Pyrotek Engineering Materials Ltd.

manufacturer

Garamonde Drive Wymbush, Milton Keynes MK8 8LN UK

+44 (0) 1908 561155

Emergency Contacts

CHEMTREC London

+44-8708-200418

CHEMTREC London

+44-2038-073798

Emergency Telephone

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Potassium Chloride EC: 231-211-8 7447-40-7 50 - 60% No
Magnesium Chloride EC: 232-094-6 7786-30-3 30 - 50% No

For the full text of the H-Statements mentioned in this Section, see Section 16 Use the indicated respiratory protection if the occupational exposure limit is exceeded and/or in case of product release (dust or vapors). Hygroscopic material. Keep product dry before insertion into molten metal. Explosion may result from sudden generation of steam.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Consult a physician.

Skin contact

Wash off with soap and water. If skin irritation persists, call a doctor.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. If symptoms persist, call a doctor.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person. Consult a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2), Water spray, pellets, Use extinguishing measures that are appropriate to local circumstances and the surrounding fire

Unsuitable media

None.

Specific hazards

Thermal decomposition can lead to release of irritating gases and vapours

Firefighter Protection

Use personal protective equipment. In the event of fire and / or explosion do not breathe fumes. In a case of a chlorine release use the respirator type B as per EN 14387.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep people away from and upwind of spill/leak.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Clean up promptly by sweeping or vacuum.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment. Avoid contact with skin and eyes. Avoid dust formation. Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Keep product dry before insertion into molten metal. Explosion may result from sudden generation of steam.

Storage

Store in original container. Protect against water and moisture. Keep container tightly closed in a dry and well-ventilated place.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. If user operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.

Hands

Protective gloves.

Eyes

Safety glasses with side-shields as per CEN/EN166:2001.

Respiratory

Respiratory protection is not necessary at normal handling, Avoid breathing dust, Dust mask EN149 - P3/FFP3 or (P2/FFP2) under dusty conditions.

Skin/Body

Long sleeved clothing.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Voc Content
No information available
Physical State Data
solid
Explosive Limits
---
Appearance
granules
Solubility In Fat
---
Kinematic Viscosity
Not applicable
Flash Point
Not flammable
Solubility In Water
partly soluble
Crystallisation Point
---
Ph
---
Flammability
Not flammable
Freezing Point
---
Odor Threshold
---
Partition Coefficient
---
Molecular Weight
---
Lower Explosive Limit
---
Bulk Density
1.0 g/cm3
Vapor Density
Not applicable
Boiling Point
Not applicable
Colour
Light yellow, Light grey
Auto Ignition Temperature
Not applicable
Solidification Point
---
Properties Status
---
Upper Explosive Limit
---
Melting Point
Not applicable
Decomposition Temperature
---
Metal Corrosion
---
Colour Intensity
---
Vapor Pressure
Not applicable
Relative Density
1.17
Odor
---
Solubility
---
Softening Point
---
Cloud Point
---
State Under Standard Conditions
---
Evaporation Rate
---
Relative Evaporation Rate
---
Physical State
solid
Density
---
Form
---
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable.

Hazardous reactions

None under normal processing.

Avoid

Exposure to moisture. Keep product dry before exposure to molten metal. Explosion may result from sudden generation of steam.

Incompatible

Incompatible with oxidising agents. Strong acids.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapours. Chlorine fumes.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Promag RI & PR-I & PI known by?

Promag RI & PR-I & PI is also known as: Pyromag RI

What is the hazard signal word for Promag RI & PR-I & PI?

The signal word is no signal word.

What is the physical form of Promag RI & PR-I & PI?

Promag RI & PR-I & PI is a solid appearing as granules with light yellow, light grey color.

What is Promag RI & PR-I & PI used for?

Flux used to remove sodium, calcium and lithium from wrought aluminum alloys.

What is the melting point of Promag RI & PR-I & PI?