NextSDS Logo
Safety Data Sheet EN

IPAC 404R

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
IPAC 404R
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial. For professional use only. Lubricant. Additive.

Uses advised against

No additional information available

Manufacturers & Suppliers

I

IPAC, Inc.

manufacturer

7600 Dublin Blvd. Suite 240 94568 Dublin, CA - USA

925-556-5530

Emergency Contacts

Emergency Contact

(800) 720-7949

7:00 AM – 5:00 PM - PST

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 60% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled and if breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

Eye contact

Rinse immediately with plenty of water.

Symptoms: pain, blinking or redness

Ingestion

Rinse mouth. Do NOT induce vomiting.

Immediate Medical Attention

Obtain medical attention if pain, blinking or redness persist. If symptoms persist, contact a doctor or physician.

Medical Treatment

All treatments should be based on observed signs and symptoms of distress in the patient.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

Do not use a heavy water stream.

Specific hazards

Fire hazard: No specific fire or explosion hazard. Explosion hazard: Product is not explosive.

Instructions

Exercise caution when fighting any chemical fire.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection. Wear fire/flame resistant/retardant clothing. Wear a self contained breathing apparatus. EN 469.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Ventilate area.

Environmental

Avoid release to the environment.

Cleanup methods

Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage.

Materials: inert solids, such as clay or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from sources of ignition - No smoking. Provide good ventilation in process area to prevent formation of vapour.

Storage

Keep only in the original container in a cool well ventilated place. Keep container closed when not in use.

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

Fire prevention

Keep away from sources of ignition - No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Avoid creating mist or spray. Avoid splashing.

Hands

Wear suitable gloves. nitrile rubber gloves. EN 374.

Eyes

Use splash goggles when eye contact due to splashing is possible. EN 166.

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. Use an approved respirator equipped with oil/mist cartridges. EN 12083.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Dark Amber
Colour Intensity
---
Form
---
Odor
Mild.
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
200 °C (PMCC)
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
No data available
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
10.0lb/US gal @15.6°C
Bulk Density
---
Density
---
Flammability
Non flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
No data available
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
0 %
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
95cSt @ 100 °C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No additional information available

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Keep away from sources of ignition.

Incompatible

strong acids. Strong bases.

Decomposition

Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

IPAC 404R LC50 fishes 1 > 1000ppm EC50 Daphnia 1 > 1000ppm ErC50(algae) > mg/l

12.1. Toxicity

Distillates(petroleum), hydrotreated heavy paraffinic(64742-54-7) EC50 Daphnia 1 > 10000 mg/l

Persistence and degradability

IPAC 404R Persistence and degradability: Moderatelybiodegradable. Not established.

Moderately biodegradable. Not established.

12.3. Bioaccumulative potential

Bioaccumulative potential

IPAC 404R Bioaccumulativepotential Not established.

Not established.

12.4. Mobility in soil

No additional information available

12.5 Results of PBT and vPvB assessment

This substance/mixture does not meet the PBT criteria of REACH, annex XIII. This substance/mixture does not meet the vPvB criteria of REACH, annex XIII.

The substance/mixture does not meet the PBT or vPvB criteria of REACH, annex XIII.

12.6. Other adverse effects

Avoid release to the environment
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose in a safe manner in accordance with local/national regulations.

Waste Codes

Not specified For disposal within the EC, the appropriate code according to the European Waste Catalogue (EWC) should be used. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for IPAC 404R?

The signal word is no signal word.

What is the physical form of IPAC 404R?

IPAC 404R is a liquid with dark amber color. It has mild. odor.

What is the solubility of IPAC 404R?

No data available

What is IPAC 404R used for?

Industrial. For professional use only. Lubricant. Additive.

What is the melting point of IPAC 404R?

The melting point is No data available and the boiling point is No data available.