NextSDS Logo
Safety Data Sheet EN

Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)

Regulatory Identifiers

CAS Number
N/A
UFI Code
11Q8-K0C6-C00Y-20P0

Identified Uses

Pipe adhesive

Manufacturers & Suppliers

Henkel AG & Co. KGaA logo

Henkel AG & Co. KGaA

manufacturer

Henkelstr. 67, 40589 Düsseldorf, Germany

+49 211 797 0

https://www.mysds.henkel.com

Emergency Contacts

Henkel information service

+49-(0)211-797-3350

around-the-clock

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Skin Irrit. Cat. 2 H315
Eye Dam. Cat. 1 H318
Carc. Cat. 2 H351
STOT SE Cat. 3 H335
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapour.
H315 Causes skin irritation.
H318 Causes serious eye damage.
H335 May cause respiratory irritation.
H336 May cause drowsiness or dizziness.
H351 Suspected of causing cancer.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P260 Do not breathe mist/vapours.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves/eye protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER or doctor.
P501 Dispose of contents/container in accordance with national regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Butanone EC: 201-159-0 78-93-3 20 - 40% Yes
tetrahydrofuran EC: 203-726-8 109-99-9 25 - 30% Yes
Cyclohexanone EC: 203-631-1 108-94-1 10 - 25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air, consult doctor if complaint persists.

Symptoms: Irritation, coughing, shortness of breath, chest tightness. Vapors may cause drowsiness and dizziness.

Skin contact

Rinse with running water and soap. Skin care. Remove contaminated clothes immediately.

Symptoms: Redness, inflammation.

Eye contact

Rinse immediately with plenty of running water (for 10 minutes), seek medical attention from a specialist.

Symptoms: Corrosive, may cause permanent damage to eyes (impairment of vision).

Ingestion

Rinse mouth, do not induce vomiting, consult a doctor.

Immediate Medical Attention

See section: Description of first aid measures

Medical Treatment

See section: Description of first aid measures

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

carbon dioxide, foam, powder, water spray jet, fine water spray

Unsuitable media

High pressure waterjet

Specific hazards

In the event of a fire, carbon monoxide (CO) and carbon dioxide (CO2) can be released.

Instructions

Cool endangered containers with water spray jet.

Firefighter Protection

Wear protective equipment. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Avoid contact with skin and eyes. Wear protective equipment. Danger of slipping on spilled product.

Environmental

Do not empty into drains / surface water / ground water.

Cleanup methods

Remove with liquid-absorbing material

Materials: sand, peat, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid naked flames, sparking and sources of ignition. Switch off electrical devices. Do not smoke, do not weld. Avoid skin and eye contact.

Storage

Store in a cool place in closed original container. Temperatures between +5 °C and +35 °C.

Hygiene

Do not eat, drink or smoke while working. Wash hands before work breaks and after finishing work.

Fire prevention

Avoid naked flames, sparking and sources of ignition. Switch off electrical devices. Do not smoke, do not weld. Avoid all sources of fire such as stoves and ovens. Switch off all electrical devices such as parabolic heaters, hot plates, storage heaters etc. in good time for them to have cooled down before commencing work. Avoid all sparks, including those occurring at electrical switches and devices.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Recommended are gloves made from Nitril rubber (Material thickness >0,1 mm, Perforation time < 30s). Gloves should be replaced after each short time contact or contamination. Available at laboratory specialized trade or at pharmacies / chemist's shops. In the case of longer contact protective gloves made from butyl rubber are recommended according to EN 374. material thickness > 0,3 mm. Perforation time > 10 minutes. In the case of longer and repeated contact please note that in practice the penetration times may be considerably shorter than those determined according to EN 374. The protective gloves must always be checked for their suitability for use at the specific workplace (e.g. mechanical and thermal stress, product compatibility, antistatic effects, etc.). The gloves must be replaced immediately at the first signs of wear and tear. The information provided by the manufacturers and given in the relevant trade association regulations for industrial safety must always be observed. We recommend that a hand care plan is drawn up in cooperation with a glove manufacturer and the trade association in accordance with the local operating conditions.

Eyes

Goggles which can be tightly sealed. Protective eye equipment should conform to EN166.

Respiratory

Suitable breathing mask when there is inadequate ventilation. Combination filter: ABEKP (EN 14387) This recommendation should be matched to local conditions.

Skin/Body

Suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless / Colorless, Light, Cloudy
Colour Intensity
---
Form
---
Odor
strong, of solvent
Odor Threshold
---
Ph
Not applicable, Product is non-soluble (in water).
Melting Point
Not applicable, Product is a liquid
Boiling Point
66 °C (150.8 °F) no method / method unknown
Flash Point
-4 °C (24.8 °F); no method / method unknown
Freezing Point
---
Softening Point
---
Solidification Point
-31 °C (-23.8 °F)
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
612 mbar (50 °C (122 °F)); 173 mbar (20 °C (68 °F))
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,960 g/cm3 no method / method unknown (23 °C (73.4 °F))
Flammability
flammable
Upper Explosive Limit
12,6 %(V);
Lower Explosive Limit
1,3 %(V);
Explosive Limits
---
Auto Ignition Temperature
215 °C (419 °F)
Decomposition Temperature
Not applicable, Substance/mixture is not self-reactive, no organic peroxide and does not decompose under foreseen conditions of use
Solubility
Partially soluble
Partition Coefficient
Not applicable (Mixture)
Solubility In Water
Partially soluble (20 °C (68 °F); Solvent: Water)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
7.300 - 15.600 mPa.s no method / method unknown
Kinematic Viscosity
7.300 - 15.600 mm2/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

None if used for intended purpose.

Hazardous reactions

See section reactivity

Avoid

None if used for intended purpose.

Incompatible

None if used properly.

Decomposition

None known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1133
Shipping Name
ADHESIVES
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?

The signal word is danger.

What is the physical form of Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?

Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE) is a liquid with colourless / colorless, light, cloudy color. It has strong, of solvent odor.

What is the solubility of Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?

Partially soluble

What is Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE) used for?

Pipe adhesive

What are the hazard statements for Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?

This substance has 6 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation.
  • H336: May cause drowsiness or dizziness.
  • H351: Suspected of causing cancer.

What is the melting point of Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?

The melting point is Not applicable, Product is a liquid and the boiling point is 66 °C (150.8 °F) no method / method unknown.