Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 11Q8-K0C6-C00Y-20P0
Identified Uses
Pipe adhesive
Manufacturers & Suppliers
Henkel AG & Co. KGaA
manufacturer
Henkelstr. 67, 40589 Düsseldorf, Germany
+49 211 797 0
https://www.mysds.henkel.com
Emergency Contacts
Henkel information service
+49-(0)211-797-3350
around-the-clock
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air, consult doctor if complaint persists.
Symptoms: Irritation, coughing, shortness of breath, chest tightness. Vapors may cause drowsiness and dizziness.
Rinse with running water and soap. Skin care. Remove contaminated clothes immediately.
Symptoms: Redness, inflammation.
Rinse immediately with plenty of running water (for 10 minutes), seek medical attention from a specialist.
Symptoms: Corrosive, may cause permanent damage to eyes (impairment of vision).
Rinse mouth, do not induce vomiting, consult a doctor.
Immediate Medical Attention
See section: Description of first aid measures
Medical Treatment
See section: Description of first aid measures
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, powder, water spray jet, fine water spray
High pressure waterjet
In the event of a fire, carbon monoxide (CO) and carbon dioxide (CO2) can be released.
Cool endangered containers with water spray jet.
Firefighter Protection
Wear protective equipment. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Avoid contact with skin and eyes. Wear protective equipment. Danger of slipping on spilled product.
Do not empty into drains / surface water / ground water.
Remove with liquid-absorbing material
Materials: sand, peat, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid naked flames, sparking and sources of ignition. Switch off electrical devices. Do not smoke, do not weld. Avoid skin and eye contact.
Store in a cool place in closed original container. Temperatures between +5 °C and +35 °C.
Do not eat, drink or smoke while working. Wash hands before work breaks and after finishing work.
Avoid naked flames, sparking and sources of ignition. Switch off electrical devices. Do not smoke, do not weld. Avoid all sources of fire such as stoves and ovens. Switch off all electrical devices such as parabolic heaters, hot plates, storage heaters etc. in good time for them to have cooled down before commencing work. Avoid all sparks, including those occurring at electrical switches and devices.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Recommended are gloves made from Nitril rubber (Material thickness >0,1 mm, Perforation time < 30s). Gloves should be replaced after each short time contact or contamination. Available at laboratory specialized trade or at pharmacies / chemist's shops. In the case of longer contact protective gloves made from butyl rubber are recommended according to EN 374. material thickness > 0,3 mm. Perforation time > 10 minutes. In the case of longer and repeated contact please note that in practice the penetration times may be considerably shorter than those determined according to EN 374. The protective gloves must always be checked for their suitability for use at the specific workplace (e.g. mechanical and thermal stress, product compatibility, antistatic effects, etc.). The gloves must be replaced immediately at the first signs of wear and tear. The information provided by the manufacturers and given in the relevant trade association regulations for industrial safety must always be observed. We recommend that a hand care plan is drawn up in cooperation with a glove manufacturer and the trade association in accordance with the local operating conditions.
Goggles which can be tightly sealed. Protective eye equipment should conform to EN166.
Suitable breathing mask when there is inadequate ventilation. Combination filter: ABEKP (EN 14387) This recommendation should be matched to local conditions.
Suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
None if used for intended purpose.
See section reactivity
None if used for intended purpose.
None if used properly.
None known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1133
- Shipping Name
- ADHESIVES
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?
The signal word is danger.
What is the physical form of Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?
Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE) is a liquid with colourless / colorless, light, cloudy color. It has strong, of solvent odor.
What is the solubility of Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?
Partially soluble
What is Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE) used for?
Pipe adhesive
What are the hazard statements for Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?
This substance has 6 hazard statements:
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer.
What is the melting point of Tangit PVC-U Special Adhesive (formerly known as Tangit ALL PRESSURE)?
The melting point is Not applicable, Product is a liquid and the boiling point is 66 °C (150.8 °F) no method / method unknown.