NextSDS Logo
Ta

Tangit Cleaner PVC-U/C ABS

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Tangit Cleaner PVC-U/C ABS

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaner for pipe bondings

Overview

Tangit Cleaner PVC-U/C ABS is a low viscosity colourless, clear substance commonly used cleaner for pipe bondings.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapor.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.

Precautionary Statements

  • P102: Keep out of reach of children.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P260: Do not breathe mist/vapours.
  • P271: Use only outdoors or in a well-ventilated area.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P501: Dispose of contents/container in accordance with national regulation.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Ltd

undefined

๐Ÿ“

Wood Lane End HP2 4RQ Hemel Hempstead Great Britain

๐ŸŒ

GB

๐Ÿ“ž

+44 (1442) 278000

๐Ÿ“ 

+44 (1442) 278071

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44 0 8701 906777

๐ŸŒ

GB

๐Ÿ•’

24 Hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Cleaner Mixture of organic solvents

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Acetone
EC: 200-662-2
67-64-1 40-60% โš ๏ธ Hazardous
METHYLETHYLCETONE
EC: 201-159-0
78-93-3 40-60% โš ๏ธ Hazardous

Composition Notes

For full text of the H - statements and other abbreviations see section 16 "Other information". Substances without classification may have community workplace exposure limits available.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air, consult doctor if complaint persists.

Symptoms:

complaint persists (after moving to fresh air)

๐Ÿ–๏ธ Skin Contact

Rinse with running water and soap. Skin care. Remove contaminated clothes immediately.

Symptoms:

Repeated exposure may cause skin dryness or cracking.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with soft jet of water or eye rinse solution for at least 5 minutes. If pains remain (intensive smarting, sensitivity to light, visual disturbance) continue flushing and contact/seek doctor or hospital.

Symptoms:

pains remain (intensive smarting, sensitivity to light, visual disturbance)

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth, do not induce vomiting, consult a doctor.

๐Ÿšจ Immediate Medical Attention Required

See section: Description of first aid measures

Medical Treatment

See section: Description of first aid measures

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
low viscosity colourless, clear
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
of methyl ethyl ketone
๐Ÿ“Š Odor Threshold
No data available / Not applicable
๐Ÿงช Ph
No data available / Not applicable
๐ŸงŠ Melting Point
No data available / Not applicable
Critical Property
๐Ÿ’จ Boiling Point
56 (132.8 F)
Critical Property
๐Ÿ”ฅ Flash Point
-16 (3.2 F); no method
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
No data available / Not applicable
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available / Not applicable
๐Ÿ’จ Vapor Pressure
No data available / Not applicable
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
No data available / Not applicable
โš–๏ธ Density
0,792 - 0,802 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
No data available / Not applicable
๐Ÿ“Š Upper Explosive Limit
14,3 %(V)
๐Ÿ“Š Lower Explosive Limit
1,5 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available / Not applicable
๐Ÿ“Š Decomposition Temperature
No data available / Not applicable
๐Ÿ’ง Solubility
No data available / Not applicable
๐Ÿ“Š Partition Coefficient
No data available / Not applicable
๐Ÿ“Š Solubility In Water
Miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
No data available / Not applicable
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

The product should only be used at workplaces with intensive ventilation/extraction.

๐Ÿงค Hand Protection

For shorttime contact (1-5 minutes) protective gloves made from special nitrile rubber are recommended according to EN 374. Material thickness > 0,2 mm. In the case of longer contact protective gloves made from butyl rubber are recommended according to EN 374. material thickness > 0.7 mm. Perforation time > 240 minutes. In the case of longer and repeated contact please note that in practice the penetration times may be considerably shorter than those determined according to EN 374. The protective gloves must always be checked for their suitability for use at the specific workplace (e.g. mechanical and thermal stress, product compatibility, antistatic effects, etc.). The gloves must be replaced immediately at the first signs of wear and tear. The information provided by the manufacturers and given in the relevant trade association regulations for industrial safety must always be observed. We recommend that a hand care plan is drawn up in cooperation with a glove manufacturer and the trade association in accordance with the local operating conditions.

๐Ÿ‘๏ธ Eye Protection

Goggles which can be tightly sealed. Protective eye equipment should conform to EN166.

๐Ÿ˜ท Respiratory Protection

If intensive ventilation/extraction is not possible then self-contained independent respiratory protection should be worn.

๐Ÿฆบ Skin/Body Protection

Suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1224

๐Ÿ“ฆ Proper Shipping Name

KETONES, LIQUID, N.O.S. (Acetone,Methyl ethyl ketone)

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Tangit Cleaner PVC-U/C ABS?

The signal word for this substance is "danger".

What is the physical form of Tangit Cleaner PVC-U/C ABS?

Tangit Cleaner PVC-U/C ABS is a liquid appearing as low viscosity colourless, clear with colourless color. It has of methyl ethyl ketone odor.

What is the solubility of Tangit Cleaner PVC-U/C ABS?

No data available / Not applicable

What is Tangit Cleaner PVC-U/C ABS used for?

Cleaner for pipe bondings

What are the hazard statements for Tangit Cleaner PVC-U/C ABS?

This substance has 3 hazard statements: H225: Highly flammable liquid and vapor. H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness.

What is the melting point of Tangit Cleaner PVC-U/C ABS?

The melting point is No data available / Not applicable and the boiling point is 56 (132.8 F).