Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Tangit Cleaner PVC-U/C ABS is a low viscosity colourless, clear substance commonly used cleaner for pipe bondings.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H225: Highly flammable liquid and vapor.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
Precautionary Statements
- P102: Keep out of reach of children.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P260: Do not breathe mist/vapours.
- P271: Use only outdoors or in a well-ventilated area.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P501: Dispose of contents/container in accordance with national regulation.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Henkel Ltd
undefined
Wood Lane End HP2 4RQ Hemel Hempstead Great Britain
GB
+44 (1442) 278000
+44 (1442) 278071
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+44 0 8701 906777
GB
24 Hours
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Cleaner Mixture of organic solvents
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetone EC: 200-662-2 | 67-64-1 | 40-60% | โ ๏ธ Hazardous |
| METHYLETHYLCETONE EC: 201-159-0 | 78-93-3 | 40-60% | โ ๏ธ Hazardous |
Composition Notes
For full text of the H - statements and other abbreviations see section 16 "Other information". Substances without classification may have community workplace exposure limits available.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air, consult doctor if complaint persists.
Symptoms:
complaint persists (after moving to fresh air)
๐๏ธ Skin Contact
Rinse with running water and soap. Skin care. Remove contaminated clothes immediately.
Symptoms:
Repeated exposure may cause skin dryness or cracking.
๐๏ธ Eye Contact
Immediately flush eyes with soft jet of water or eye rinse solution for at least 5 minutes. If pains remain (intensive smarting, sensitivity to light, visual disturbance) continue flushing and contact/seek doctor or hospital.
Symptoms:
pains remain (intensive smarting, sensitivity to light, visual disturbance)
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth, do not induce vomiting, consult a doctor.
๐จ Immediate Medical Attention Required
See section: Description of first aid measures
Medical Treatment
See section: Description of first aid measures
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
The product should only be used at workplaces with intensive ventilation/extraction.
๐งค Hand Protection
For shorttime contact (1-5 minutes) protective gloves made from special nitrile rubber are recommended according to EN 374. Material thickness > 0,2 mm. In the case of longer contact protective gloves made from butyl rubber are recommended according to EN 374. material thickness > 0.7 mm. Perforation time > 240 minutes. In the case of longer and repeated contact please note that in practice the penetration times may be considerably shorter than those determined according to EN 374. The protective gloves must always be checked for their suitability for use at the specific workplace (e.g. mechanical and thermal stress, product compatibility, antistatic effects, etc.). The gloves must be replaced immediately at the first signs of wear and tear. The information provided by the manufacturers and given in the relevant trade association regulations for industrial safety must always be observed. We recommend that a hand care plan is drawn up in cooperation with a glove manufacturer and the trade association in accordance with the local operating conditions.
๐๏ธ Eye Protection
Goggles which can be tightly sealed. Protective eye equipment should conform to EN166.
๐ท Respiratory Protection
If intensive ventilation/extraction is not possible then self-contained independent respiratory protection should be worn.
๐ฆบ Skin/Body Protection
Suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
1224
๐ฆ Proper Shipping Name
KETONES, LIQUID, N.O.S. (Acetone,Methyl ethyl ketone)
โ ๏ธ Transport Hazard Class
3
๐ Packing Group
II
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Tangit Cleaner PVC-U/C ABS?
The signal word for this substance is "danger".
What is the physical form of Tangit Cleaner PVC-U/C ABS?
Tangit Cleaner PVC-U/C ABS is a liquid appearing as low viscosity colourless, clear with colourless color. It has of methyl ethyl ketone odor.
What is the solubility of Tangit Cleaner PVC-U/C ABS?
No data available / Not applicable
What is Tangit Cleaner PVC-U/C ABS used for?
Cleaner for pipe bondings
What are the hazard statements for Tangit Cleaner PVC-U/C ABS?
This substance has 3 hazard statements: H225: Highly flammable liquid and vapor. H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness.
What is the melting point of Tangit Cleaner PVC-U/C ABS?
The melting point is No data available / Not applicable and the boiling point is 56 (132.8 F).