NextSDS Logo
Safety Data Sheet EN

Universal Spray-on Grease with MoS2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Universal Spray-on Grease with MoS2
Product Form
Aerosol
Product Code
115300

Regulatory Identifiers

CAS Number
N/A
UFI Code
KDD0-2056-W00F-3KW0

Identified Uses

Aerosol product-Lubricating agent

Manufacturers & Suppliers

WEICON GmbH & Co. KG logo

WEICON GmbH & Co. KG

manufacturer

Königsberger Str. 255, 48157 Münster, Germany

+49 251 93220

http://www.weicon.de

Emergency Contacts

EMERGENCY CONTACT – UK, UAE, South Africa

++44 1865 407333

24h

EN

TRANSPORT EMERGENCY CONTACT - UK, UAE, South Africa

++44 1865 407333

24h

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurized container: may burst if heated.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
propane EC: 200-827-9 74-98-6 10 - 25% Yes
butane EC: 203-448-7 106-97-8 10 - 25% Yes
propan-2-ol EC: 200-661-7 67-63-0 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Symptoms: respiratory tract irritation, coughing

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: irritation, redness

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

Extremely flammable aerosol. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. In the case of aerosols being ruptured, care should be taken due to the rapid escape of the pressurized contents and propellant. If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Put on appropriate personal protective equipment.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.

Materials: water, inert dry material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Avoid breathing vapor or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous.

Storage

Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. Recommended : 1 - 4 hours (breakthrough time): nitrile rubber 4 - 8 hours (breakthrough time): Viton®/butyl rubber

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended : organic vapor (Type AX) and particulate filter

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Solidification Point
---
Molecular Weight
---
Odor
Characteristic.
Solubility In Water
Not available.
Auto Ignition Temperature
Not applicable.
Form
---
Properties Status
---
Ph
Not applicable.
Colour Intensity
---
Decomposition Temperature
Not available.
Density
0.72 g/cm³ [20°C (68°F)]
Colour
Black.
Crystallisation Point
---
Flash Point
Closed cup: Not applicable.
State Under Standard Conditions
---
Cloud Point
---
Explosive Limits
---
Solubility
---
Boiling Point
Not available.
Voc Content
---
Odor Threshold
Not available.
Bulk Density
---
Flammability
Extremely flammable in the presence of the following materials or conditions: open flames, sparks and static discharge. Highly flammable in the presence of the following materials or conditions: heat.
Dynamic Viscosity
---
Lower Explosive Limit
Lower: 0.6%
Physical State Data
aerosol
Physical State
Aerosol.
Vapor Density
---
Relative Density
---
Upper Explosive Limit
Upper: 3.2%
Melting Point
Not available.
Evaporation Rate
---
Softening Point
---
Appearance
Aerosol.
Relative Evaporation Rate
---
Vapor Pressure
350 kPa (2625 mm Hg)
Metal Corrosion
---
Freezing Point
---
Partition Coefficient
Not applicable.
Kinematic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame).

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Universal Spray-on Grease with MoS2?

The signal word is danger.

What is the physical form of Universal Spray-on Grease with MoS2?

Universal Spray-on Grease with MoS2 is a aerosol. appearing as aerosol. with black. color. It has characteristic. odor.

What is Universal Spray-on Grease with MoS2 used for?

Aerosol product-Lubricating agent

What are the hazard statements for Universal Spray-on Grease with MoS2?

This substance has 2 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurized container: may burst if heated.

What is the melting point of Universal Spray-on Grease with MoS2?