NextSDS Logo
Safety Data Sheet EN

DOW CORNING 550(R) FLUID

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DOW CORNING 550(R) FLUID
Product Form
Liquid
Product Code
02288494
Chemical Name
Silicone

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

D

Dow Corning Corporation

manufacturer

South Saginaw Road, Midland, Michigan 48686

(989) 496-6000

Emergency Contacts

Dow Corning Corporation

(989) 496-5900

CHEMTREC

(800) 424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

None present. This is not a hazardous material as defined in the OSHA Hazard Communication Standard.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No first aid should be needed.

Skin contact

No first aid should be needed.

Eye contact

Immediately flush with water.

Ingestion

No first aid should be needed.

Medical Treatment

Treat according to person's condition and specifics of exposure.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

On large fires use dry chemical, foam or water spray. On small fires use carbon dioxide (CO2), dry chemical or water spray. Water can be used to cool fire exposed containers.

Specific hazards

None.

Instructions

Determine the need to evacuate or isolate the area according to your local emergency plan. Use water spray to keep fire exposed containers cool.

Firefighter Protection

Self-contained breathing apparatus and protective clothing should be worn in fighting large fires involving chemicals.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use with adequate ventilation. Avoid eye contact. Use reasonable care.

Storage

Store away from oxidizing materials.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Local Ventilation: None should be needed. General Ventilation: Recommended. Provide ventilation to control vapor exposure within inhalation guidelines when handling at elevated temperatures.

Hands

Handle in accordance with good industrial hygiene and safety practices.

Eyes

Use proper protection - safety glasses as a minimum.

Respiratory

No respiratory protection should be needed.

Skin/Body

Washing at mealtime and end of shift is adequate.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
Not determined.
State Under Standard Conditions
---
Vapor Density
Not determined.
Physical State Data
liquid
Solubility
---
Upper Explosive Limit
Not determined.
Flash Point
631.4 °F / 333 °C (Cleveland Open Cup) > 213.8 °F / > 101 °C (Closed Cup)
Boiling Point
> 65 °C
Colour
Colorless
Solidification Point
---
Melting Point
Not determined.
Physical State
Liquid
Colour Intensity
---
Voc Content
---
Dynamic Viscosity
---
Decomposition Temperature
---
Relative Evaporation Rate
---
Metal Corrosion
---
Crystallisation Point
---
Solubility In Water
Not determined.
Appearance
---
Molecular Weight
---
Vapor Pressure
Not determined.
Relative Density
1.065
Kinematic Viscosity
125 cSt
Freezing Point
---
Flammability
---
Properties Status
---
Partition Coefficient
---
Softening Point
---
Auto Ignition Temperature
Not determined.
Bulk Density
---
Odor
Odorless
Solubility In Fat
---
Evaporation Rate
---
Form
---
Density
---
Odor Threshold
---
Cloud Point
---
Explosive Limits
---
Lower Explosive Limit
Not determined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

None.

Incompatible

Oxidizing material can cause a reaction.

Decomposition

Thermal breakdown of this product during fire or very high heat conditions may evolve the following decomposition products: Carbon oxides and traces of incompletely burned carbon compounds. Silicon dioxide. Formaldehyde.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DOW CORNING 550(R) FLUID?

The signal word is no signal word.

What is the physical form of DOW CORNING 550(R) FLUID?

DOW CORNING 550(R) FLUID is a liquid with colorless color. It has odorless odor.

What is the melting point of DOW CORNING 550(R) FLUID?

The melting point is Not determined. and the boiling point is > 65 °C.