Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tantalum ICP Standard Solution 10000 mg/l Ta
- Product Code
- 2548
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemical
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Carl Roth GmbH + Co. KG
manufacturer
Schoemperlenstraße 3-5, 76185 Karlsruhe, Germany
+49/(0)721 5606-0
Emergency Contacts
Poison Centre Munich
+49/(0)89 19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If breathing is difficult, give oxygen. Administer artificial respiration if breathing has stopped. Seek medical advice immediately.
After contact with skin: Rinse with plenty of water for at least 10 minutes. Immediately remove contaminated clothes. Apply calcium gluconate gel and massage into the skin until the pain subsides, in between rinse with water and apply fresh gel. Continue gel therapy for another 15 minutes after the pain has subsided. If no calcium gluconate gel is available, apply several dressings thoroughly moistened with 20 % calcium gluconate solution. Medical advice absolutely required!
Rinse immediately for 15 minutes with plenty of water with the eyelid held wide open. Seek medical advice. Protect unharmed eye.
Rinse out mouth and drink a glass of water. Do not induce vomiting. If possible, add calcium gluconate solution. Call for a doctor immediately.
Immediate Medical Attention
Seek medical advice immediately (inhalation), Medical advice absolutely required (skin), Seek medical advice (eye), Call for a doctor immediately (swallowing).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions. CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
For this substance/mixture no limitations of extinguishing agents are given.
In case of fire, the following can be released: Hydrogen fluoride (HF), Nitrogen oxides (NOx). In the event of fire development of hazardous combustion gases or vapours possible. Carbon monoxide and carbon dioxide.
Firefighter Protection
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
observe emergency procedures, consult an expert
Do not allow to enter sewers/ground water or penetrate the soil.
Absorb with liquid-binding material (e.g. Rotisorb® Art.-Nr. 1710.1). Dispose of the material collected according to regulations.
Materials: Rotisorb® Art.-Nr. 1710.1
Related Products
Similar products with comparable safety profiles
Tantalum ICP Standard Solution 10000 mg/l Ta
---
TDS Calibration Solution, 1500 mg/L (ppm) @ 25°C/77°F
---
Vanadium ICP standard traceable to SRM from NIST NH₄VO₃ in HNO₃ 15% 10000 mg/l V CertiPUR®
---
Vanadium ICP standard traceable to SRM from NIST NH₄VO₃ in HNO₃ 2-3% 1000 mg/l V CertiPUR®
---
Sodium Reference Standard Solution 1000 ± 10 mg/L as Na⁺ in H₂O
---
Mono-Component =<1000 ppm element/ion reference solution
---
Hach Molybdenum Reference Standard Solution 1000 +/- 10mg/L as Mo(+6)
---
Antimony, plasma standard solution, Specpure®, Sb 1000μg/ml
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
This substance should be handled with particular care. Handling corresponding to laboratory safety guidelines.
Store receptacle in a well ventilated area. Store under lock and key and with access restricted to technical experts or their assistants only. Keep container tightly sealed.
Keep respiratory protective device available.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves: The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Butylcaoutchouc, thickness: 0,7 mm. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: Value for the permeation: Level ≥ 6. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. As protection from splashes gloves made of the following materials are suitable: Butylcaoutchouc, thickness: 0,7 mm. Value for the permeation: Level ≥ 6.
Tightly sealed goggles
Required when vapours/aerosols are generated. Filter E.
Acid resistant protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
has a corrosive effect
Strong reaction possible with: Metals Alkali metals alkali hydroxides Strong bases fluorine potassium permanganate Oxides of phosphorus
Strong Heating
various metals
Hydrogen fluoride In case of fire: see item 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2922
- Shipping Name
- CORROSIVE LIQUID, TOXIC, N.O.S. (HYDROGEN FLUORIDE, NITRIC ACID)
- Transport Class
- 8 (6.1)
- Packing Group
- III
Warning: Corrosive substances.
Warning: Corrosive substances.
Warning: Corrosive substances.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tantalum ICP Standard Solution 10000 mg/l Ta?
The signal word is danger.
What is the physical form of Tantalum ICP Standard Solution 10000 mg/l Ta?
Tantalum ICP Standard Solution 10000 mg/l Ta is a liquid with colourless color. It has pungent odor.
What is Tantalum ICP Standard Solution 10000 mg/l Ta used for?
Laboratory chemical
What are the hazard statements for Tantalum ICP Standard Solution 10000 mg/l Ta?
This substance has 5 hazard statements:
- H290: May be corrosive to metals.
- H302 + H332: Harmful if swallowed or if inhaled.
- H311: Toxic in contact with skin.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of Tantalum ICP Standard Solution 10000 mg/l Ta?