NextSDS Logo
Safety Data Sheet EN

anti-p40 (BC28) Mouse Monoclonal Primary Antibody

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
anti-p40 (BC28) Mouse Monoclonal Primary Antibody
Product Code
07394420001

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals, Refer to product literature for further details.

Manufacturers & Suppliers

R

Roche Diagnostics Deutschland GmbH

manufacturer

Sandhoferstrasse 116, 68305 Mannheim, Deutschland

+496217590

Emergency Contacts

Werkschutzzentrale Roche Diagnostics GmbH

+49(0)621-759-2203

Mainz

+49(0)6131-19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P261 Avoid breathing mist or vapours.
P273 Avoid release to the environment.
P280 Wear protective gloves.
P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mixture of: 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-2H-isothiazol-3-one (3:1) 55965-84-9 0.0025 - 0.025% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Specific hazards

Hazardous combustion products: Carbon oxides

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. Persons susceptible to skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used. Handle all samples as if potentially infectious, using safe laboratory procedures. As the sensitivity and titer of potential pathogens in the sample material can vary, the operator must optimize pathogen inactivation and follow the appropriate measures according to local safety regulations.

Storage

Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Do not eat, drink, or smoke in the laboratory area. Do not pipette by mouth. Wash hands before breaks and at the end of workday.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material: Nitrile rubber Break through time: > 30 min Glove thickness: > 0,11 mm In case of contact through splashing: Material: butyl-rubber Break through time: > 480 min Glove thickness: > 0,4 mm

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
light yellow
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
No data available
Ph
7,55 - 7,65
Melting Point
No data available
Boiling Point
No data available
Flash Point
does not flash
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1,005 g/cm3
Flammability
Does not sustain combustion.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
Hazardous decomposition products formed under fire conditions.
Solubility
---
Partition Coefficient
No data available
Solubility In Water
completely miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Exposure to light.

Incompatible

No data available

Decomposition

No decomposition if stored and applied as directed. In case of fire hazardous decomposition products may be produced such as: Carbon oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for anti-p40 (BC28) Mouse Monoclonal Primary Antibody?

The signal word is warning.

What is the physical form of anti-p40 (BC28) Mouse Monoclonal Primary Antibody?

anti-p40 (BC28) Mouse Monoclonal Primary Antibody is a liquid appearing as liquid with light yellow color.

What is anti-p40 (BC28) Mouse Monoclonal Primary Antibody used for?

Laboratory chemicals, Refer to product literature for further details.

What are the hazard statements for anti-p40 (BC28) Mouse Monoclonal Primary Antibody?

This substance has 2 hazard statements:

  • H317: May cause an allergic skin reaction.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of anti-p40 (BC28) Mouse Monoclonal Primary Antibody?

The melting point is No data available and the boiling point is No data available.