Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Floor Tile Adhesive
- Product Code
- 1712001
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Construction Adhesive
Manufacturers & Suppliers
DAP Global Inc.
manufacturer
2400 Boston Street Suite 200, Baltimore, MD 21224-4723
888-327-8477
Emergency Contacts
Transportation
1-800-535-5053
Transportation
1-352-323-3500
Poison Control
1-800-222-1222
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Hazard Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Petroleum hydrocarbon oil | 64742-52-5 | 10 - 30% | No |
| Butadiene-styrene copolymer | 9003-55-8 | 7 - 13% | No |
| Clay | 1332-58-7 | 3 - 7% | No |
| Poly(oxy-1,2-ethanediyl), alpha(4-nonylphenyl) omega- hydroxy, branched | 127087-87-0 | 1 - 5% | Yes |
| Urea | 57-13-6 | 1 - 5% | No |
| Ethylene glycol | 107-21-1 | 1 - 5% | Yes |
| Glycol ethers | --- | 0.1 - 1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If you experience difficulty in breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.
In case of contact, wash skin immediately with soap and water.
In case of contact, immediately flush eyes with large quantities of water for at least 15 minutes until irritation subsides. Get medical attention immediately.
Symptoms: irritation
If swallowed, DO NOT INDUCE VOMITING. Get medical attention immediately.
Immediate Medical Attention
Get medical attention immediately if continued difficulty in breathing is experienced, after eye contact, or if swallowed.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water
No Information
Use water spray to cool exposed surfaces.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Contain spilled material and remove with inert absorbent. Dispose of contaminated absorbent, container and unused contents in accordance with local, state and federal regulations. Use personal protective equipment as necessary. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations. Scrape up dried material and place into containers.
No Information
remove with inert absorbent. Scrape up dried material and place into containers.
Materials: inert absorbent
Related Products
Similar products with comparable safety profiles
Weldwood Floor Tile Adhesive
---
Multi Purpose Ceramic Tile Adhesive
---
Multi-Purpose Floor Adhesive
---
Weldwood Multi-Purpose Floor Adhesive
---
Touch N Seal Storm Bond 1K PU Roof Tile Adhesive - Cylinder
---
Touch N Foam Landscape Exterior Filler Adhesive
---
SmartBond Subfloor Construction Adhesive Foam
---
Touch N Seal Storm Bond 2 Roof Tile Adhesive HFO 600 Kit A Side
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Use only with adequate ventilation. Ensure fresh air entry during application and drying. Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid creating dust.
Avoid excessive heat and freezing. Do not store at temperatures above 120 °F (49 °C). Store away from caustics and oxidizers. Keep containers tightly closed.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Excessive heat and freezing.
strong bases and oxidizing agents.
Normal decomposition products, i.e., COx, NOx.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Floor Tile Adhesive?
The signal word is no signal word.
What is the physical form of Floor Tile Adhesive?
Floor Tile Adhesive is a paste appearing as white to off-white . It has slight odor.
What is Floor Tile Adhesive used for?
Construction Adhesive
What are the hazard statements for Floor Tile Adhesive?
This substance has 1 hazard statement:
- Not a hazardous substance or mixture.