NextSDS Logo
Safety Data Sheet EN

Multi Purpose Ceramic Tile Adhesive

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Multi Purpose Ceramic Tile Adhesive
Product Code
7705001

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Construction Adhesive

Manufacturers & Suppliers

D

DAP Global Inc.

manufacturer

2400 Boston Street Suite 200, Baltimore, MD 21224-4723

888-327-8477

Emergency Contacts

Transportation

1-800-535-5053

Transportation

1-352-323-3500

Poison Control

1-800-222-1222

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Limestone 1317-65-3 80 - 100% No
Clay 1332-58-7 1 - 5% No
Ethylene glycol 107-21-1 0.5 - 1.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If you experience difficulty in breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.

Skin contact

In case of contact, wash skin immediately with soap and water.

Eye contact

In case of contact, immediately flush eyes with large quantities of water for at least 15 minutes until irritation subsides. Get medical attention immediately.

Symptoms: irritation

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Get medical attention immediately.

Immediate Medical Attention

Get medical attention immediately if continued difficulty in breathing is experienced, after eye contact, or if swallowed.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water

Specific hazards

No Information

Instructions

Use water spray to cool exposed surfaces.

Firefighter Protection

Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Contain spilled material and remove with inert absorbent. Dispose of contaminated absorbent, container and unused contents in accordance with local, state and federal regulations. Use personal protective equipment as necessary. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations. Scrape up dried material and place into containers.

Environmental

No Information

Cleanup methods

remove with inert absorbent, Scrape up dried material

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Use only with adequate ventilation. Ensure fresh air entry during application and drying. Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Construction and repair activities can adversely affect indoor air quality. Consult with occupants or a representative (i.e. maintenance, building manager, industrial hygienist, or safety officer) to determine ways to minimize impact. Do not sand, dry sweep, dry scrape, drill, saw, beadblast, mechanically chip, pulverize or otherwise machine existing resilient flooring, backing, lining felt, or asphaltic "cut-back" adhesives. These products may contain either asbestos fibers or crystalline silica. Avoid creating dust. Inhalation of such dust is a cancer and respiratory tract hazard. See current edition of the Resilient Floor Covering Institute's publication "Recommended Work Practices for Removal of Resilient Floor Coverings", for detailed information and instructions addressed to the task of removing all resilient floor covering materials.

Storage

Avoid excessive heat and freezing. Do not store at temperatures above 120 °F (49 °C). Store away from caustics and oxidizers. Keep containers tightly closed.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Appearance
White to Off-White
Density
1.69 - 2.72 g/cm3
Voc Content
---
Explosive Limits
---
Metal Corrosion
---
Form
---
Kinematic Viscosity
---
Flash Point
Seta Closed Cup: 100 °C
Colour
---
Auto Ignition Temperature
Not Established
Crystallisation Point
---
Odor Threshold
Not Established
Softening Point
---
Physical State Data
liquid
Cloud Point
---
Ph
Between 7.0 and 12.0
Physical State
Paste
Odor
Very Slight Ammonia
Vapor Pressure
Not Established
Relative Density
---
Properties Status
---
Lower Explosive Limit
N.E.
Evaporation Rate
Slower Than n-Butyl Acetate
Flammability
Non-Flammable
Boiling Point
100 - 100 °C
Colour Intensity
---
Upper Explosive Limit
N.E.
Decomposition Temperature
Not Established
Solidification Point
---
State Under Standard Conditions
---
Dynamic Viscosity
Not Established
Solubility
---
Relative Evaporation Rate
---
Bulk Density
---
Freezing Point
Not Established
Partition Coefficient
Not Established
Solubility In Fat
---
Melting Point
---
Vapor Density
Heavier Than Air
Solubility In Water
Not Established
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Avoid

Excessive heat and freezing.

Incompatible

strong bases and oxidizing agents.

Decomposition

Normal decomposition products, i.e., COx, NOx.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Multi Purpose Ceramic Tile Adhesive?

The signal word is no signal word.

What is the physical form of Multi Purpose Ceramic Tile Adhesive?

Multi Purpose Ceramic Tile Adhesive is a paste appearing as white to off-white . It has very slight ammonia odor.

What is Multi Purpose Ceramic Tile Adhesive used for?

Construction Adhesive