NextSDS Logo
Safety Data Sheet EN

Gorilla Heavy Duty Construction Adhesive Ultimate

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Gorilla Heavy Duty Construction Adhesive Ultimate

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Construction Adhesive

Manufacturers & Suppliers

The Gorilla Glue Company logo

The Gorilla Glue Company

manufacturer

2101 E. Kemper Road, Cincinnati, Ohio 45241

513-271-3300

http://www.gorillatough.com

Emergency Contacts

Emergency Contact

(800) 966-3458

During Business Hours

Emergency Contact

(800) 420-7186

Outside Business Hours

Prosar

1-800-420-7186

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

STOT RE Cat. 2 H373

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H373 May cause damage to organs through prolonged or repeated exposure

Precautionary Statements

P261 Avoid breathing vapors, mist, or spray.
P272 Contaminated work clothing must not be allowed out of the workplace.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/container in accordance with local, regional, national, territorial, provincial, and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Silane, ethenyltrimethoxy- 2768-02-7 1 - 5% No
Titanium dioxide 13463-67-7 0.1 - 1% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Symptoms: None known.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. In the case of skin irritation or allergic reactions see a physician.

Symptoms: None known.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Do not rub affected area. If eye irritation persists: Get medical advice/attention.

Symptoms: None known.

Ingestion

Rinse mouth. Never give anything by mouth to an unconscious person. Do not induce vomiting without medical advice. If symptoms persist, call a physician.

Symptoms: None known.

Immediate Medical Attention

If you feel unwell, seek medical advice (show the label if possible). If eye irritation persists: Get medical advice/attention. If symptoms persist, call a physician.

Medical Treatment

Small amounts of methanol (CAS 67-56-1) are formed by hydrolysis and released upon curing. Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog). Carbon dioxide (CO2). Foam. Dry chemical. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

Do not use a heavy water stream. Use of heavy stream of water may spread fire.

Specific hazards

Fire Hazard: Not flammable. Explosion Hazard: Product is not explosive. Reactivity: Hazardous reactions will not occur under normal conditions.

Instructions

Do not allow run-off from fire fighting to enter drains or water courses.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Upon arrival at the scene, a first responder is expected to recognize the presence of dangerous goods, protect oneself and the public, secure the area, and call for the assistance of trained personnel as soon as conditions permit.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Dispose of waste safely and in accordance with local, state, federal, national, and international regulations.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle in accordance with good industrial hygiene and safety procedures.

Storage

Keep away from food, drink and animal feeding stuffs. Recommended storage temperature. 10 - 35 °C. Keep from freezing. Keep container tightly closed and dry. Protect from moisture. Product cures with moisture.

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking, or smoking and again when leaving work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Boiling Point
Not available
Bulk Density
---
Solubility
Insoluble in water.
Metal Corrosion
---
Voc Content
---
Relative Density
---
Melting Point
Not available
Molecular Weight
---
Explosive Limits
---
Odor Threshold
Not available
Auto Ignition Temperature
Not available
Colour Intensity
---
Vapor Density
---
Density
1.56 g/cm³
Freezing Point
Not available
Physical State Data
solid
Crystallisation Point
---
Vapor Pressure
---
Flammability
Not available
Kinematic Viscosity
Not available
Decomposition Temperature
Not available
Appearance
White
Partition Coefficient
Not available
Colour
---
Upper Explosive Limit
Not available
Form
---
Cloud Point
---
Relative Evaporation Rate
---
Odor
Not available
Solidification Point
---
Flash Point
>100 °C (212 °F)
Dynamic Viscosity
Not available
Lower Explosive Limit
Not available
Evaporation Rate
---
Properties Status
---
Solubility In Water
Insoluble in water.
Ph
Not available
Physical State
Paste
Softening Point
---
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended handling and storage conditions (see section 7).

Reactivity

Product cures with moisture.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Direct sunlight. Extremely high or low temperatures. Keep from freezing.

Incompatible

Water.

Decomposition

None under normal use and recommended storage conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Gorilla Heavy Duty Construction Adhesive Ultimate?

The signal word is warning.

What is the physical form of Gorilla Heavy Duty Construction Adhesive Ultimate?

Gorilla Heavy Duty Construction Adhesive Ultimate is a paste appearing as white . It has not available odor.

What is the solubility of Gorilla Heavy Duty Construction Adhesive Ultimate?

Insoluble in water.

What is Gorilla Heavy Duty Construction Adhesive Ultimate used for?

Construction Adhesive

What are the hazard statements for Gorilla Heavy Duty Construction Adhesive Ultimate?

This substance has 1 hazard statement:

  • H373: May cause damage to organs through prolonged or repeated exposure

What is the melting point of Gorilla Heavy Duty Construction Adhesive Ultimate?

The melting point is Not available and the boiling point is Not available.