Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DAP Heavy Duty Construction Adhesive
- Product Code
- 070798275089, 70798275096, 070798275102
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Construction Adhesive
Manufacturers & Suppliers
DAP Global Inc.
manufacturer
2400 Boston Street Suite 200, Baltimore, MD 21224-4723
888-327-8477
Emergency Contacts
Transportation
1-800-535-5053
Transportation
1-352-323-3500
Poison Control
1-800-222-1222
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Limestone | 1317-65-3 | 30 - 60% | Yes |
| Diethylene glycol dibenzoate | 120-55-8 | 1 - 5% | Yes |
| Magnesite | 546-93-0 | 1 - 5% | Yes |
| Dipropylene glycol dibenzoate | 27138-31-4 | 1 - 5% | No |
| Potassium tripolyphosphate | 13845-36-8 | 0.5 - 1.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If breathing is difficult, leave the area to obtain fresh air.
Remove and wash contaminated clothing. Wash off immediately with soap and plenty of water for at least 15 minutes.
In case of contact, immediately flush eyes with large quantities of water for at least 15 minutes until irritation subsides.
Symptoms: irritation
If swallowed, DO NOT INDUCE VOMITING.
Immediate Medical Attention
If continued breathing difficulty is experienced, get medical attention immediately. Get medical aid if symptoms persist. Get medical attention immediately for eye contact. Get medical attention immediately for ingestion.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water
No special protective measures against fire required.
Use water spray to cool exposed surfaces.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Contain spilled material and remove with inert absorbent. Dispose of contaminated absorbent, container and unused contents in accordance with local, state and federal regulations. Use personal protective equipment as necessary. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations. Scrape up dried material and place into containers.
No Information
remove with inert absorbent, absorb with inert material, Scrape up dried material and place into containers
Materials: inert absorbent, inert material
Related Products
Similar products with comparable safety profiles
DAP All Purpose Construction Adhesive
---
Max Strength Heavy Duty Construction Adhesive
---
DAP Strong Anchoring Adhesive Part A Resin
---
DAP Foamboard Construction Adhesive
---
Gorilla Heavy Duty Construction Adhesive
---
DAP Strong Anchoring Adhesive Part B Catalyst
---
DAP All Purpose Adhesive & Filler Part B Hardener
---
Gorilla Heavy Duty Construction Adhesive Ultimate
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Avoid breathing vapor and contact with eyes, skin and clothing. Wash thoroughly after handling.
Close container after each use. Do not store at temperatures above 120 °F (49 °C). Store containers away from excessive heat and freezing. Store away from caustics and oxidizers.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Excessive heat and freezing.
Incompatible with strong bases and oxidizing agents.
Normal decomposition products, i.e., COx, NOx.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DAP Heavy Duty Construction Adhesive?
The signal word is warning.
What is the physical form of DAP Heavy Duty Construction Adhesive?
DAP Heavy Duty Construction Adhesive is a solid appearing as paste with white to off-white color. It has slight odor.
What is DAP Heavy Duty Construction Adhesive used for?
Construction Adhesive
What are the hazard statements for DAP Heavy Duty Construction Adhesive?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.