Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER
- Product Code
- 594399
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaner
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Potassium hydroxide | 1310-58-3 | 10 - 30% | No |
| Tetrapotassium pyrophosphate | 7320-34-5 | 1 - 5% | No |
| Poly(oxy-1,2-ethanediyl), .alpha.-{4-(1,1,3,3-tet | 9002-93-1 | 1 - 5% | No |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air.
Immediately wash skin thoroughly with soap and water.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes.
Do not induce vomiting.
Immediate Medical Attention
Get medical attention (inhalation, skin contact). Seek immediate medical attention (eye contact). Get immediate medical attention (ingestion).
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use media appropriate for surrounding material.
Not available.
May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up. Do not allow product to enter sewer or waterways.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE C-AK PRECLEAN 2960 ALKALINE CLEANER
---
BONDERITE C-AK EC-76 ALKALINE CLEANER
---
BONDERITE C-AK 6751-L AERO ALKALINE CLEANER
---
BONDERITE C-AK 4316 L AERO ALKALINE CLEANER
---
BONDERITE C-AK 375 D ALKALINE CLEANER known as EC 375 D
---
BONDERITE C-AK T51 ALKALINE CLEANER
---
BONDERITE C-AK VITKL AERO ALKALINE CLEANER
---
BONDERITE C-AK CLEANER ALKALINE CLEANER known as PARCO CLEANER 2076
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing mists or aerosols of this product. NEVER ADD WATER TO PRODUCT. For dilutions, add product slowly to water while stirring. Use caution; heat may be generated. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Ship and store above 40° F. Protect from freezing.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
Will not occur.
Keep away from heat, ignition sources and incompatible materials.
This product reacts with acids. Adding water to this product may cause localized overheating and splattering.
None identified.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3266
- Shipping Name
- Corrosive liquid, basic, inorganic, n.o.s. (Potassium hydroxide, Tetrapotassium pyrophosphate)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER?
The signal word is danger.
What is the physical form of BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER?
BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER is a liquid with amber to yellowish color. It has mild odor.
What is the solubility of BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER?
Complete Water
What is BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER used for?
Cleaner
What are the hazard statements for BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER?
This substance has 2 hazard statements:
- H290: MAY BE CORROSIVE TO METALS.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
What is the melting point of BONDERITE C-AK 2819 ALKALINE CLEANER known as AQUENCE 2819 CLEANER?
The melting point is Not determined and the boiling point is > 100 °C (> 212°F) Aqueous solution.