Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE ECCOBOND FP4802 10CCMU
- Product Form
- 1-c- epoxide adhesive
- Product Code
- 46372
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silica, vitreous | 60676-86-0 | 30 - 60% | Yes |
| Bisphenol-F Epichlorhydrin resin | 9003-36-5 | 10 - 30% | Yes |
| Formaldehyde, polymer with 2-(2-propenyl)phenol | 27924-97-6 | 10 - 30% | Yes |
| Si-oxide amorphous (fumed) | 7631-86-9 | 5 - 10% | Yes |
| Quartz (SiO2), <1% respirable | 14808-60-7 | 1 - 5% | Yes |
Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Get medical attention. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
Vapors may accumulate in low or confined areas, travel considerable distance to source of ignition, and flash back. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear. In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Ensure adequate ventilation. Remove all sources of ignition. Keep unnecessary personnel away. Wear appropriate personal protective equipment. Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wear suitable protective clothing, safety glasses and gloves. Keep container closed.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store in a dry place. Store in original container until ready to use.
Wash thoroughly after handling. When using do not eat, drink or smoke.
Remove all sources of ignition. Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight.
Oxidizing agents. Acids. Bases. Amines.
Oxides of carbon. Phenolics. Toxic fumes. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE ECCOBOND FP4802 10CCMU?
The signal word is danger.
What is the physical form of LOCTITE ECCOBOND FP4802 10CCMU?
LOCTITE ECCOBOND FP4802 10CCMU is a liquid with black color.
What is the solubility of LOCTITE ECCOBOND FP4802 10CCMU?
Not miscible or difficult to mix Water
What are the hazard statements for LOCTITE ECCOBOND FP4802 10CCMU?
This substance has 4 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE ECCOBOND FP4802 10CCMU?
The melting point is Not available. and the boiling point is Not available..