Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE ECCOBOND FP0097 30CC
- Product Code
- 3149845
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Encapsulant
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silica, vitreous | 60676-86-0 | 60 - 80% | Yes |
| hexahydro-4-methylphthalic anhydride | 19438-60-9 | 10 - 30% | Yes |
| Si-oxide amorphous (fumed) | 7631-86-9 | 5 - 10% | Yes |
| 7-Oxabicyclo[4.1.0]hept-3-ylmethyl 7-oxabicyclo[4.1.0]heptane-3-carboxylate | 2386-87-0 | 1 - 5% | Yes |
| Substituted phthalic anhydride | 34090-76-1 | 1 - 5% | Yes |
| Silanamine, 1,1,1-trimethyl-N-(trimethylsilyl)-, hydrolysis products with silica | 68909-20-6 | 0.1 - 1% | Yes |
| Carbon black - Nano | 1333-86-4 | 0.1 - 1% | Yes |
| Aluminium oxide - non fibrous form | 1344-28-1 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention.
Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Check for and remove any contact lenses. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Water or foam may cause frothing. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up.
Do not allow product to enter sewer or waterways. Do not allow material to contaminate ground water system.
Scrape up as much material as possible.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Keep container closed.
For safe storage, store at or below -40 °C (-40°F) Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep in a cool, well ventilated area away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing. Polymerization may occur at elevated temperature or in the presence of incompatible materials.
Store away from incompatible materials. Heat, flames, sparks and other sources of ignition. Exposure to moisture.
Strong acids and oxidizing agents. Water, Amines, Alkalis, Alcohols.
Oxides of carbon. Oxides of nitrogen. Phenolics. Hydrocarbons. Aldehydes. Irritating organic vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE ECCOBOND FP0097 30CC?
The signal word is danger.
What is the physical form of LOCTITE ECCOBOND FP0097 30CC?
LOCTITE ECCOBOND FP0097 30CC is a viscous, liquid with black color. It has aromatic odor.
What is the solubility of LOCTITE ECCOBOND FP0097 30CC?
Insoluble Water; Partially miscible ketones
What is LOCTITE ECCOBOND FP0097 30CC used for?
Encapsulant
What are the hazard statements for LOCTITE ECCOBOND FP0097 30CC?
This substance has 7 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H318: CAUSES SERIOUS EYE DAMAGE.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
- H341: SUSPECTED OF CAUSING GENETIC DEFECTS.
- H373: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE ECCOBOND FP0097 30CC?
The melting point is Not applicable, Product is a liquid and the boiling point is Not applicable, Decomposes before boiling point is reached.