NextSDS Logo
Safety Data Sheet EN

LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG
Product Code
2996380

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Acrylic Adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 MAY CAUSE AN ALLERGIC SKIN REACTION.

Precautionary Statements

P261 Avoid breathing dust or fumes.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2,4-diethyl-9H-thioxanthen-9-one 82799-44-8 0.1 - 1% Yes
Photoinitiator --- 0.1 - 1% Yes
2-Ethylhexyl acrylate 103-11-7 0.1 - 1% Yes

Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.

Skin contact

Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn. Cover affected areas with clean sheeting or gauze and seek immediate medical attention.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

If symptoms develop and persist, get medical attention.

Immediate Medical Attention

Seek immediate medical attention for skin contact.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.

Unsuitable media

Not available.

Specific hazards

In case of fire toxic gases can be released.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not empty into drains / surface water / ground water.

Cleanup methods

Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always be careful around molten material. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted.

Storage

Store in a cool, dry, well-ventilated area.

Hygiene

Do not wear contact lenses.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Work should be done in an adequately ventilated area (i.e., ventilation sufficient to maintain concentrations below one half of the PEL and other relevant standards). Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination.

Hands

Insulated gloves are strongly recommended when working with molten adhesive.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.

Respiratory

Use NIOSH approved respirator if there is potential to exceed exposure limit(s). Observe OSHA regulations for respirator use (29 CFR 1910.134).

Skin/Body

Long sleeved clothing are strongly recommended when working with molten adhesive.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Crystallisation Point
---
Flash Point
> 200 °C (> 392°F) ASTM D 93-96 Flash point
Vapor Density
---
Relative Density
0.90 - 0.98 at 25 °C (77°F)
Flammability
Not applicable
Colour Intensity
---
State Under Standard Conditions
---
Odor
Acrylic
Colour
Light yellow
Odor Threshold
Not available.
Properties Status
---
Molecular Weight
---
Solubility In Water
---
Appearance
Light yellow
Vapor Pressure
0.01 - 1.00 mbar (25 °C (77°F)) Literature
Explosive Limits
---
Dynamic Viscosity
Not available.
Metal Corrosion
---
Physical State Data
solid
Cloud Point
---
Density
---
Auto Ignition Temperature
Not available.
Softening Point
---
Boiling Point
Not applicable, Decomposes at 149°C (300°F).
Relative Evaporation Rate
---
Decomposition Temperature
> 149 °C
Voc Content
0.1 - 0.3 %
Ph
Not applicable, Product is an aerosol. Concentrate is non-polar/aprotic.
Solubility
Not soluble Water
Melting Point
Not applicable, Decomposes.
Solubility In Fat
---
Lower Explosive Limit
Not available.
Form
---
Partition Coefficient
Not available.
Evaporation Rate
---
Freezing Point
---
Upper Explosive Limit
Not available.
Bulk Density
---
Kinematic Viscosity
Not available.
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

Not available.

Hazardous reactions

Polymerization occurs when exposed to white light, ultraviolet light or heat.

Avoid

UV light. Extremes of temperature and direct sunlight.

Incompatible

Oxidizing agents. Heat, sunlight, or UV light. Polymerises in the presence of sunlight.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors. Oxides of carbon.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG?

The signal word is warning.

What is the physical form of LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG?

LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG is a solid appearing as light yellow with light yellow color. It has acrylic odor.

What is the solubility of LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG?

Not soluble Water

What is LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG used for?

Acrylic Adhesive

What are the hazard statements for LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG?

This substance has 1 hazard statement:

  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.

What is the melting point of LOCTITE DURO-TAK UV 7050 ULTRA DR-F181KGKG?

The melting point is Not applicable, Decomposes. and the boiling point is Not applicable, Decomposes at 149°C (300°F)..