NextSDS Logo
Safety Data Sheet EN

TEROSON PU 8519 PRIMER

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TEROSON PU 8519 PRIMER
Product Form
Primer, containing solvents
Product Code
1252496

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2
Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Resp. Sens. Cat. 1
Skin Sens. Cat. 1
STOT SE Cat. 3

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 HIGHLY FLAMMABLE LIQUID AND VAPOUR.
H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H334 MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
H336 MAY CAUSE DROWSINESS OR DIZZINESS.

Precautionary Statements

P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P284 [In case of inadequate ventilation] wear respiratory protection.
P303 + P361 + P353 If on skin (or hair): Take off immediately all contaminated clothing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P342 + P311 If experiencing respiratory symptoms: Call a poison center or physician.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or physician if you feel unwell.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Methyl ethyl ketone 78-93-3 30 - 60% Yes
Ethyl acetate 141-78-6 10 - 30% Yes
1,3-Benzenedicarboxylic acid, polymer with 1,4-benzenedicarboxylic acid, 1,6-diisocyanatohexane, 2,2-dimethyl-1,3-propanediol, 1,2-e 1067676-51-0 10 - 30% Yes
Carbon black - Nano 1333-86-4 5 - 10% Yes
1,3-Bis(isocyanatomethyl)cyclohexane, trimethylolpropane copolymer 39527-44-1 5 - 10% Yes
n-butyl acetate 123-86-4 5 - 10% Yes
Acrylic acid 79-10-7 0.1 - 1% Yes
4-isocyanatosulphonyltoluene 4083-64-1 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. For severe exposures, get under safety shower after removing clothing, then get medical attention. For lesser exposure, seek medical attention if irritation develops or persists after area is washed. Wash clothing before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Symptoms: Workplace vapors have produced reversible corneal epithelial edema impairing vision.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Eyes: If cornea is burned, instill antibiotic steroid preparation frequently. Skin: Treat symptomatically as for contact dermatitis or thermal burns. Respiratory: Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

High volume water jet.

Specific hazards

During a fire, MDI vapors and other irritating, highly toxic gases may be generated by thermal decomposition or combustion. At temperatures above 204.4°C (400°F), polymeric MDI can polymerize and decompose which can cause pressure build-up in closed containers. Explosive rupture is possible. Sealed containers at elevated temperatures or contaminated with water may rupture explosively.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate the hazard area and deny entry to unnecessary and unprotected personnel. Remove all sources of ignition. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.

Small spill

For minor spills, absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution.

Large spill

Large quantities may be pumped into closed, but not sealed containers for disposal.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Remove all sources of ignition. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up. If temporary control of isocyanate vapor is required, a blanket of protein foam may be placed over spill.

Materials: Sawdust or other absorbent, protein foam.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Exposure to vapors of heated MDI can be extremely dangerous. Use only with adequate ventilation. Protect from moisture. Keep container closed. Employee education and training in the safe use and handling of this compound are required under the OSHA Hazard Communication Standard.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store away from heat, sparks, flames, or other sources of ignition. Do not let moisture contaminate this material.

Hygiene

Wash thoroughly after handling.

Fire prevention

Store away from heat, sparks, flames, or other sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
11 mm2/s
State Under Standard Conditions
---
Vapor Density
---
Upper Explosive Limit
Not available.
Physical State Data
liquid
Form
---
Physical State
liquid
Auto Ignition Temperature
Not available.
Molecular Weight
---
Solubility In Water
---
Relative Density
0.9800
Lower Explosive Limit
0.82 %
Odor Threshold
Not available.
Crystallisation Point
---
Cloud Point
---
Vapor Pressure
470 mbar (55 °C (131°F)) no method / method unknown 94 hPa (20 °C (68°F)) 360 hPa (50 °C (122°F))
Voc Content
Not available.
Flammability
Not applicable
Ph
Not applicable, Product reacts with water.
Odor
Ester-like, Ketone
Explosive Limits
---
Solubility In Fat
---
Solidification Point
---
Relative Evaporation Rate
---
Decomposition Temperature
Not available.
Freezing Point
---
Solubility
Partially miscible Water
Colour Intensity
---
Partition Coefficient
Not available.
Evaporation Rate
---
Density
---
Properties Status
---
Metal Corrosion
---
Flash Point
-2.5 °C (27.5 °F) DIN EN ISO 1523:2002
Dynamic Viscosity
3 - 14 mPa.s
Boiling Point
80 °C (176°F) Boiling point
Colour
Black
Melting Point
Not applicable, Product is a liquid
Bulk Density
---
Appearance
---
Softening Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Contact with moisture, other materials which can react with isocyanates, or temperatures above 204.4°C (400°F), may cause polymerization.

Avoid

Elevated temperatures. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials. Contamination with water.

Incompatible

Water. Acids and bases. Amines. Oxidizing agents. Alcohols. Ammonia.

Decomposition

Oxides of carbon. Oxides of nitrogen. Irritating and toxic gases or fumes may be released during a fire. Hydrogen cyanide. MDI vapors and aerosols. Isocyanates.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1139
Shipping Name
Coating solution
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TEROSON PU 8519 PRIMER?

The signal word is danger.

What is the physical form of TEROSON PU 8519 PRIMER?

TEROSON PU 8519 PRIMER is a liquid with black color. It has ester-like, ketone odor.

What is the solubility of TEROSON PU 8519 PRIMER?

Partially miscible Water

What are the hazard statements for TEROSON PU 8519 PRIMER?

This substance has 6 hazard statements:

  • H225: HIGHLY FLAMMABLE LIQUID AND VAPOUR.
  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
  • H336: MAY CAUSE DROWSINESS OR DIZZINESS.

What is the melting point of TEROSON PU 8519 PRIMER?

The melting point is Not applicable, Product is a liquid and the boiling point is 80 °C (176°F) Boiling point.