Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE
- Product Code
- 702198, 96321_314086
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Not available.
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isocyanic acid, polymethylenepolyphenylene ester, polymer with a-hydro-w-hydroxypoly[oxy(methyl-1,2-ethanediyl)] | 53862-89-8 | 10 - 30% | No |
| Methylenebis(phenylisocyanate) | 101-68-8 | 1 - 5% | No |
| Polymeric diphenylmethane diisocyanate | 9016-87-9 | 1 - 5% | No |
| o-(p-Isocyanatobenzyl)phenyl isocyanate | 5873-54-1 | 1 - 5% | No |
Notes
Non hazardous components
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.
Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours. Extreme asthmatic reactions can be life threatening.
Remove contaminated clothing and shoes. Wipe off paste with paper towel or cloth. Rinse with running water and soap. Wash contaminated clothing before reuse. Thoroughly clean shoes before reuse. Discard any shoes or clothing items that cannot be decontaminated. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical attention immediately.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Seek medical attention immediately.
Immediate Medical Attention
Seek medical attention immediately.
Medical Treatment
Persons with asthmatic-type conditions, chronic bronchitis, other chronic respiratory diseases or recurrent skin eczema or sensitization should be excluded from working with isocyanates.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.
Water may be an ineffective extinguishing medium. Do not use high volume water jet.
At higher temperatures isocyanate may be released. Sealed containers at elevated temperatures or contaminated with water may rupture explosively.
In case of fire, keep containers cool with water spray. Keep unnecessary personnel away.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Cover spill area with suitable absorbent material. Saturate absorbent material with neutralization solution and mix. Wait 15 minutes. Collect material in open-head metal containers. Repeat applications of decontamination solution with scrubbing, followed by absorbent until surface is decontaminated.
Large quantities may be pumped into closed, but not sealed containers for disposal.
Do not empty into drains / surface water / ground water.
Cover spill area with suitable absorbent material. Saturate absorbent material with neutralization solution and mix. Wait 15 minutes. Collect material in open-head metal containers. Repeat applications of decontamination solution with scrubbing, followed by absorbent until surface is decontaminated.
Materials: suitable absorbent material, neutralization solution, decontamination solution
Related Products
Similar products with comparable safety profiles
LOCTITE EA 3463 known as Pipe Repair Kit EPOXY STICK
---
LOCTITE PC 7210 B known as Loctite 7210 (PipeR.) KitComp B
---
LOCTITE 5117 THREAD SEALANT known as LOCTITE® PIPE JOINT COMPOUND 1
---
LOCTITE 561 known as Sticks Assortment PIPE THREAD
---
LOCTITE 565 LOW STRENGTH THREAD SEALANT known as LOCT 565 PST PIPE 10L EN/CH/JP
---
LOCTITE 565 known as 565 PIPE SEALANT PST(R) 250 ML.
---
LOCTITE PC 7257 B known as LOCTITE FIXMAST MAGROUT 1GA PTB
---
LOCTITE PC 7257 B known as LOCTITE FIXMAST MAGROUT 5GA PTB
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Wear suitable protective clothing, gloves and eye/face protection. Protect from moisture. Employee education and training in the safe use and handling of this compound are required under the OSHA Hazard Communication Standard. Do not taste or swallow.
Very sensitive against humidity. Store original or opened drums absolutely dry and always close it air-tight. Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep from freezing. Protect from direct sunlight. Store between 0 °C (32°F) and 40 °C (104°F).
Wash thoroughly after handling. Employee education and training in the safe use and handling of this compound are required.
Store away from heat, sparks, flames, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Exothermic. Polymerization may occur at elevated temperature or in the presence of incompatible materials.
Avoid moisture. Contamination with water. Extremes of temperature and direct sunlight. Container can be pressurised by carbon dioxide due to reaction with humid air and/or water. Protect from direct sunlight. Do not freeze.
Water. Moisture. Humid air and/or water will produce carbon dioxide which will pressurize the container. Amines. Alcohols. Strong acids and strong bases.
Upon decomposition, this product may yield gaseous nitrogen oxides, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Hydrogen cyanide. Isocyanate vapors Toxic and irritating gases.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE?
The signal word is danger.
What is the physical form of LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE?
LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE is a fiberglass cloth coated with viscous white resin with white color. It has odorless odor.
What is the solubility of LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE?
Insoluble Water, Not determined Acetone
What is LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE used for?
Not available.
What are the hazard statements for LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE?
This substance has 7 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H332: HARMFUL IF INHALED.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE PC 5070 TAPE known as Pipe Repair Kit TAPE?
The melting point is Not available. and the boiling point is 648.9 °C (1,200°F).