Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL
- Product Code
- 1187974
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Catalyst
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Poly[oxy(methyl-1,2-ethanediyl)], a-(2-aminomethylethyl)-w-(2-aminomethylethoxy)- | 9046-10-0 | 80 - 100% | Yes |
| Polypropyleneglycol | 25322-69-4 | 1 - 5% | Yes |
IDH number: 1187974 Product name: LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Get medical attention. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Do not induce vomiting. If vomiting occurs, prevent aspiration by keeping the patient's head below the knees. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Do not use high volume water jet.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Keep unnecessary personnel away. In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Refer to Section 8 'Exposure Controls / Personal Protection' prior to clean up.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE STYCAST S 5225 PTA known as STYCAST S 5225 A (1.5lb)
---
LOCTITE STYCAST 2CN CL known as STYCAST 2CN CLR 2LB
---
LOCTITE STYCAST 5877 PTB
---
LOCTITE STYCAST 5952 RD PTA known as STYCAST 5952 PTA RED 15LB GA
---
LOCTITE STYCAST US 1000 PTB 5L
---
LOCTITE STYCAST 2850GT BK known as STYCAST 2850GT BLK 18# (SPEC)
---
LOCTITE STYCAST 2651-40 BK
---
LOCTITE STYCAST 2850FT BK
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Remove all sources of ignition. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Wear suitable protective clothing, safety glasses and gloves. Refer to Section 8. Remove clothing and protective equipment contaminated before entering in food areas. When using do not eat, drink or smoke. Keep container closed. Avoid generating static electricity while handling. Use proper grounding procedures when handling near flammable or explosive materials.
Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use. Store in a dry place. Avoid moisture. Store in original container until ready to use. Store away from incompatible materials identified in section 10.
Wash thoroughly after handling. Remove clothing and protective equipment contaminated before entering in food areas. When using do not eat, drink or smoke.
Remove all sources of ignition. Avoid generating static electricity while handling. Use proper grounding procedures when handling near flammable or explosive materials.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
High temperatures. Keep away from heat, ignition sources and incompatible materials. Avoid moisture. Take measures to prevent the build-up of electrostatic charges.
Strong oxidizing agents. Acids. Isocyanates.
Oxides of carbon. Toxic and irritating gases. Irritating organic vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2735
- Shipping Name
- Polyamines, liquid, corrosive, n.o.s. (Polyoxy propylene diamine)
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL?
The signal word is danger.
What is the physical form of LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL?
LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL is a liquid with transparent, light yellow color. It has ammoniacal odor.
What is LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL used for?
Catalyst
What are the hazard statements for LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL?
This substance has 2 hazard statements:
- H302: HARMFUL IF SWALLOWED
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE
What is the melting point of LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL?
The melting point is Not applicable, Product is a liquid and the boiling point is > 250 °C (> 482°F).