Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A
- Product Code
- 1663304
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Acrylics
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methyl methacrylate | 80-62-6 | 10 - 30% | Yes |
| High boiling methacrylate | --- | 10 - 30% | Yes |
| methacrylic acid | 79-41-4 | 10 - 30% | Yes |
| Methacrylate ester | --- | 10 - 30% | Yes |
| Zinc neodecanoate | 27253-29-8 | 0.1 - 1% | Yes |
| Methacrylic acid, zinc salt | 13189-00-9 | 0.1 - 1% | Yes |
| Talc | 14807-96-6 | 0.1 - 1% | Yes |
| Methacrylate ester | --- | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding eyelids open all the time.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry chemical or carbon dioxide.
Vapors may accumulate in low or confined areas, travel considerable distance to source of ignition, and flash back. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Refer to Section 8 'Exposure Controls / Personal Protection' prior to clean up.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B
---
LOCTITE AA H4500 490ML PT B
---
LOCTITE AA H8110 B known as LOCTITE H8110 SPEED 490ML PT B
---
LOCTITE LB 8150 known as Loctite 8150 500g EGFD
---
LOCTITE AA H4500 A known as SPDBNDR H4500 490 ML CQ PART A
---
LOCTITE HHD 8190R 50ML PTB
---
LOCTITE AA H8700 DC400ML PT B
---
LOCTITE LB 8156 known as Loctite 8156 500g EGFD
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling.
Store between 2 °C (35.6 °F) and 8 °C (46.4 °F). Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Protect from direct sunlight. Maintain head space in storage containers to support oxygen requirements of the inhibitor(s).
Wash thoroughly after handling.
Do not smoke; extinguish all flames, pilot lights, and heaters; turn off stoves, electrical tools and appliances, and any other sources of ignition. Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Polymerization may occur at elevated temperatures or upon depletion of inhibitor.
Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight. Loss of polymerization inhibitor. Loss of dissolved air. Inert gas blanketing. Oxidizing conditions. Freezing conditions. Do not mix in batches greater than 100 grams (0.22 pounds) unless you plan to use immediately.
Oxidizing agents. Reducing agents. Acids. Bases. Free radical initiators. Peroxides. Inert gases. Oxygen scavengers. Metals.
Oxides of carbon. Oxides of nitrogen. Hydrogen cyanide. Styrene. Toxic fumes. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1133
- Shipping Name
- Adhesives
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A?
The signal word is danger.
What is the physical form of LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A?
LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A is a liquid, paste with yellow color. It has acrylic odor.
What is LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A used for?
Acrylics
What are the hazard statements for LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A?
This substance has 5 hazard statements:
- H225: HIGHLY FLAMMABLE LIQUID AND VAPOR.
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H318: CAUSES SERIOUS EYE DAMAGE.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
What is the melting point of LOCTITE AA HF8150 A known as LOCTITE HF8150 50ML PT A?
The melting point is Not available. and the boiling point is Not available..