NextSDS Logo
Safety Data Sheet EN

LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B
Product Code
1416306_AB8110

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Acrylics

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

ORGANIC PEROXIDE
Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Skin Sens. Cat. 1
Repr. Cat. 1B

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H242 HEATING MAY CAUSE A FIRE.
H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H360 MAY DAMAGE FERTILITY OR THE UNBORN CHILD.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P234 Keep only in original packaging.
P240 Ground and bond container and receiving equipment.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical attention.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 Store in a well-ventilated place.
P405 Store locked up.
P410 Protect from sunlight.
P411 + P235 Store at temperatures not exceeding 38 °C (100.4 °F). Keep cool.
P420 Store separately.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Benzoyl peroxide 94-36-0 10 - 30% Yes
Epichlorohydrin-4,4'-isopropylidene diphenol resin 25068-38-6 10 - 30% Yes
Benzyl butyl phthalate 85-68-7 10 - 30% Yes
Ethene, homopolymer 9002-88-4 10 - 30% Yes
ammonium iron(3+) hexakis(cyano-C)ferrate(4-) 25869-00-5 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding eyelids open all the time. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Danger of decomposition if exposed to heat. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Remove all sources of ignition. Ensure adequate ventilation. Wear appropriate personal protective equipment. Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat, spark and flame. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Use only with adequate ventilation. Keep container closed.

Storage

Store at or below 38 °C (100.4 °F). Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Protect from direct sunlight.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid, Paste
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Blue
Colour Intensity
---
Form
---
Odor
Slight, Characteristic
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
> 93 °C (> 199.4 °F) 1,013 hPa
Flash Point
> 93.00 °C (> 199.4 °F) Pensky Martens closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.1674
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Slight Water
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
3.04 %
Metal Corrosion
---
Dynamic Viscosity
10,000 - 25,000 cp
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Polymerization may occur at elevated temperature or in the presence of incompatible materials.

Avoid

Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight. Do not mix in batches greater than 100 grams (0.22 pounds) unless you plan to use immediately.

Incompatible

Oxidizing agents. Acids. Bases.

Decomposition

Oxides of carbon. Phenolics. Toxic fumes. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3109
Shipping Name
Organic peroxide type F, liquid (Dibenzoyl peroxide, stable dispersion in water, <=42%) (Butyl-benzyl-phthalate)
Transport Class
5.2
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B?

The signal word is danger.

What is the physical form of LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B?

LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B is a liquid, paste with blue color. It has slight, characteristic odor.

What is the solubility of LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B?

Slight Water

What is LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B used for?

Acrylics

What are the hazard statements for LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B?

This substance has 5 hazard statements:

  • H242: HEATING MAY CAUSE A FIRE.
  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H360: MAY DAMAGE FERTILITY OR THE UNBORN CHILD.

What is the melting point of LOCTITE AA HF8000 B known as LOCTITE HF8000 SPEED 40/CS PT B?

The melting point is Not available. and the boiling point is > 93 °C (> 199.4 °F) 1,013 hPa.