Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT PA 7811 PELLETS/1000 LBS.
- Product Code
- 38964
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hotmelt adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
CHEMTREC
1-703-527-3887
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Notes
Hazardous Component(s): None
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.
Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn. Cover affected areas with clean sheeting or gauze and seek immediate medical attention.
Symptoms: Molten adhesive may cause severe burns.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
Ingestion of solid adhesive is not expected to be hazardous. If symptoms develop and persist, get medical attention.
Immediate Medical Attention
Seek immediate medical attention for skin burns. Seek medical attention for eye contact or if symptoms develop and persist after inhalation or ingestion.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.
In case of fire, keep containers cool with water spray.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow material to contaminate ground water system.
Sweep up spilled material. Avoid creating dust. Keep in suitable and closed containers for disposal.
Materials: suitable and closed containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not place wet or damp solid into melt tank. Follow suggested application temperature. Always be careful around molten material. Avoid skin contact with molten resins. Do not wear contact lenses. Avoid dust formation.
Keep cool in accordance with information on label and in Technical Data Sheets.
Do not wear contact lenses.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Work should be done in an adequately ventilated area (i.e., ventilation sufficient to maintain concentrations below one half of the PEL and other relevant standards). Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination.
Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.
Solid Resin: Dust safety masks are recommended when the potential for dust inhalation exists. Molten Resin: Use a NIOSH approved air-purifying respirator with an organic vapor cartridge.
Long sleeved clothing are strongly recommended when working with molten adhesive.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Excessive heat.
Oxidizing agents. Acids. Bases.
Carbon dioxide, carbon monoxide and irritating and/or toxic gases and particulate may be generated by thermal decomposition or combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT PA 7811 PELLETS/1000 LBS.?
The signal word is no signal word.
What is the physical form of TECHNOMELT PA 7811 PELLETS/1000 LBS.?
TECHNOMELT PA 7811 PELLETS/1000 LBS. is a solid with amber color. It has odorless odor.
What is TECHNOMELT PA 7811 PELLETS/1000 LBS. used for?
Hotmelt adhesive
What is the melting point of TECHNOMELT PA 7811 PELLETS/1000 LBS.?
The melting point is 137.7 °C (279.9 °F) (Softening Point) and the boiling point is > 280.0 °C (> 536°F).