Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE C-MC MC-97 MAINTENANCE CLEANER
- Synonyms
- MC-97
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
preservation agents
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Diethylene glycol monobutyl ether | 112-34-5 | 5 - 10% | Yes |
| Nonylphenol ethoxylated, propoxylated | 68891-11-2 | 1 - 5% | Yes |
| Sodium EDTA | 64-02-8 | 1 - 5% | Yes |
| trisodium nitrilotriacetate | 5064-31-3 | 0.1 - 1% | Yes |
| Triethanolamine | 102-71-6 | 1 - 5% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person immediately to fresh air.
Flush with large amounts of water.
Rinse immediately with plenty of water.
Do not induce vomiting.
Immediate Medical Attention
Seek medical attention if symptoms develop or persist (inhalation); Obtain medical attention if irritation persists (skin); Seek medical advice (eyes); Get immediate medical attention (ingestion).
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Do not direct a solid stream of water or foam into hot, burning pools; this may result in frothing and increase fire intensity.
Empty containers retain product residue, so obey hazard warnings and handle empty containers as if they were full.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Related Products
Similar products with comparable safety profiles
BONDERITE C-MC 21130 MAINTENANCE CLEANER
---
BONDERITE C-MC A-300 MAINTENANCE CLEANER
---
BONDERITE C-MC AQUAPREP MAINTENANCE CLEANER
---
BONDERITE C-MC AQUAPREP MAINTENANCE CLEANER
---
BONDERITE C-MC 200 ALKALINE MAINTENANCE CLEANER
---
BONDERITE C-MC 2235 MAINT. CLEANER known as PARCO MAINTENANCE CLEANER 2235
---
BONDERITE C-MC 5884 AERO MAINTENANCE CLEANER JC4.5KG
---
BONDERITE C-IC 110 ACID CLEANER
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists of this product. NEVER ADD WATER TO PRODUCT. For dilutions, add product slowly to water while stirring. Use caution; heat may be generated. Provide adequate ventilation. Wash thoroughly after handling. Do not take internally. Do not cut or weld on empty drums. Sufficient vapors from residues may be present to cause explosion and serious injury and/or death. Open container only in well-ventilated area or with respiratory protection.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.
Wash thoroughly after handling.
Do not cut or weld on empty drums.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
This product may react with strong reducing agents.
None under normal processing.
Store away from incompatible materials.
Nitrites may react with organic amines to form nitrosamines which can cause cancer. Do not mix this product with fluids which contain NITRITES/NITRATES. NITROSAMINE may be formed. Oxidizing agents.
Carbon dioxide, carbon monoxide and irritating and/or toxic gases and particulate may be generated by thermal decomposition or combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is BONDERITE C-MC MC-97 MAINTENANCE CLEANER known by?
BONDERITE C-MC MC-97 MAINTENANCE CLEANER is also known as: MC-97
What is the hazard signal word for BONDERITE C-MC MC-97 MAINTENANCE CLEANER?
The signal word is danger.
What is the physical form of BONDERITE C-MC MC-97 MAINTENANCE CLEANER?
BONDERITE C-MC MC-97 MAINTENANCE CLEANER is a liquid with colourless / colorless color. It has mild odor.
What is the solubility of BONDERITE C-MC MC-97 MAINTENANCE CLEANER?
Complete Water
What is BONDERITE C-MC MC-97 MAINTENANCE CLEANER used for?
preservation agents
What are the hazard statements for BONDERITE C-MC MC-97 MAINTENANCE CLEANER?
This substance has 3 hazard statements:
- H318: CAUSES SERIOUS EYE DAMAGE.
- H351: SUSPECTED OF CAUSING CANCER.
- H373: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of BONDERITE C-MC MC-97 MAINTENANCE CLEANER?
The melting point is Not available. and the boiling point is > 212 °F (> 100°C).