Product Information

Product Name
LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe
Product Code
232741

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 4
Skin Irrit. Cat. 2
Eye Dam. Cat. 1
Skin Sens. Cat. 1

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H227 COMBUSTIBLE LIQUID
H315 CAUSES SKIN IRRITATION
H317 MAY CAUSE AN ALLERGIC SKIN REACTION
H318 CAUSES SERIOUS EYE DAMAGE

Precautionary Statements

P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 Store in a well-ventilated place.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Cyclohexyl methacrylate 101-43-9 30 - 60% Yes
methacrylic acid 79-41-4 5 - 10% Yes
Silica, amorphous, fumed, cryst.-free 112945-52-5 1 - 5% Yes
1,3-Butylene glycol dimethacrylate 1189-08-8 1 - 5% Yes
Acrylic acid 79-10-7 1 - 5% Yes
Tert-butyl perbenzoate 614-45-9 0.1 - 1% Yes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention.

Skin contact

Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and footwear. Get medical attention. Wash clothing before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Uncontrolled polymerization may occur at high temperatures resulting in explosions or rupture of storage containers. Vapors may travel considerable distance to source of ignition and flash back.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material. Scrape up as much material as possible.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Do not taste or swallow.

Storage

Store at or below 38 °C (100.4 °F). Keep in a cool, well ventilated area away from heat, sparks and open flame.

Hygiene

Wash thoroughly after handling.

Fire prevention

Make sure containers are properly grounded before use or transfer of material. Keep away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Opaque, Light yellow, Dark amber
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
69.5 °C (157.1 °F) Pensky Martens closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
---
Relative Density
1.0113
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
8 % (Acrylic Acid)
Lower Explosive Limit
2 % (Acrylic Acid)
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Not available.
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
< 0.23 % (Adhesive and Activator mixed)
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing. Polymerization may occur at elevated temperature or in the presence of incompatible materials.

Avoid

Heat, flames, sparks and other sources of ignition. Freezing conditions. Store away from incompatible materials. Direct sunlight. UV light. Loss of polymerization inhibitor. Inert gas blanketing. Moisture.

Incompatible

Strong oxidizing agents. Strong reducing agents. Free radical initiators. Oxygen scavengers. Acids and bases. Heavy metals.

Decomposition

Oxides of carbon. Irritating organic vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
NA 1993
Shipping Name
Combustible liquid, n.o.s. (Methylacrylic acid)
Transport Class
Combustible Liquid
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe?

The signal word is danger.

What is the physical form of LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe?

LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe is a liquid with opaque, light yellow, dark amber color. It has characteristic odor.

What is the solubility of LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe?

Not available.

What is LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe used for?

Adhesive

What are the hazard statements for LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe?

This substance has 4 hazard statements:

  • H227: COMBUSTIBLE LIQUID
  • H315: CAUSES SKIN IRRITATION
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION
  • H318: CAUSES SERIOUS EYE DAMAGE

What is the melting point of LOCTITE AA 332 MAGNET BONDER known as Loctite(R) 332 Structural Adhe?

The melting point is Not available. and the boiling point is Not available..