Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT PUR 5003
- Product Form
- Polyurethane adhesive
- Product Code
- 2646818
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polycaprolactone-copolyester polyurethane | --- | 1 - 5% | Yes |
| Methylenebis(phenylisocyanate) | 101-68-8 | 1 - 5% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air. If not breathing, give artificial respiration.
Cool melted product on skin with plenty of water. Do not remove solidified product. Immediately wash skin thoroughly with soap and water. Get immediate medical attention.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
If material is ingested, immediately contact a physician or poison control center. DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get immediate medical attention. Seek medical attention. Immediately contact a physician or poison control center.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Sealed containers at elevated temperatures or contaminated with water may rupture explosively.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear. Keep unnecessary personnel away.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Keep unnecessary personnel away. Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid skin and eye contact. Avoid breathing vapors or mists of this product. Wash thoroughly after handling.
Keep containers closed when not in use. Do not let moisture contaminate this material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Not available.
Will not occur.
Container can be pressurised by carbon dioxide due to reaction with humid air and/or water.
Reacts with alcohols and amines. Reacts with water.
Thermal decomposition can lead to release of irritating gases and vapors. Hydrogen cyanide. Oxides of carbon. Oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT PUR 5003?
The signal word is danger.
What is the physical form of TECHNOMELT PUR 5003?
TECHNOMELT PUR 5003 is a solid with light yellow color. It has characteristic odor.
What are the hazard statements for TECHNOMELT PUR 5003?
This substance has 7 hazard statements:
- EUH019: STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H332: HARMFUL IF INHALED.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H335: VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
- MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
What is the melting point of TECHNOMELT PUR 5003?
The melting point is Not available. and the boiling point is Not available..