NextSDS Logo
Safety Data Sheet EN

TECHNOMELT PUR 9022 known as PURMELT QR 9022

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT PUR 9022 known as PURMELT QR 9022
Product Code
1217909

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Urethane adhesive

Uses advised against

This product is for industrial use only.

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Resp. Sens. Cat. 1
Skin Sens. Cat. 1
STOT RE Cat. 1

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H242 STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H334 MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
H335 VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
H372 CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.

Precautionary Statements

P264 Wash affected area thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, eye protection, and face protection.
P285 In case of inadequate ventilation wear respiratory protection.
P304 + P341 IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P342 + P311 If experiencing respiratory symptoms: Call a poison center or physician.
P352 IF ON SKIN: Wash with plenty of water.
P362 Take off contaminated clothing.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
Do not breathe dust or fumes.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Poly[oxy(methyl-1,2-ethanediyl)], a-hydro-w-hydroxy-, polymer with Dynacoll RP 360 and 1,1'-Methylenebis[4-isocyanatobenzene] --- 80 - 100% Yes
Methylenebis(phenylisocyanate) 101-68-8 1 - 5% Yes
o-(p-Isocyanatobenzyl)phenyl isocyanate 5873-54-1 0.1 - 1% Yes
Methyl methacrylate 80-62-6 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion. If breathing is difficult, give oxygen.

Skin contact

Cover affected areas with clean sheeting or gauze and seek immediate medical attention. Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

If material is ingested, immediately contact a physician or poison control center.

Immediate Medical Attention

Cover affected areas with clean sheeting or gauze and seek immediate medical attention. Seek medical attention (for eye contact). If material is ingested, immediately contact a physician or poison control center.

Medical Treatment

Persons with asthmatic-type conditions, chronic bronchitis, other chronic respiratory diseases or recurrent skin eczema or sensitization should be excluded from working with isocyanates.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

No special environmental precautions required. Do not allow material to contaminate ground water system.

Cleanup methods

If product is spilled in the solid state, pick up and place in an appropriate waste disposal container. If product is spilled in the molten state, allow product to solidify before scraping up and disposing of in an appropriate waste disposal container.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

This product should only be heated to recommended temperatures. Hazards of pyrolysis products emitted are unknown and may be hazardous to health. If recommended temperature is exceeded, there is an increased possibility that MDI may be released. Equipment should be closely monitored. Always be careful around molten material. Follow suggested application temperature. Avoid skin contact with molten resins. Use caution if using container unloading equipment that inverts product, in order to avoid dislodging product prematurely.

Storage

Store between -20 °C (-4°F) and 50 °C (122°F). Avoid moisture. Store at room temperature. Keep container closed. Do not let moisture contaminate this material. Do not reseal if moisture contamination is suspected.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Molecular Weight
---
Odor Threshold
Not available.
Appearance
---
Vapor Pressure
Not available.
Solubility In Fat
---
Physical State Data
solid
Solidification Point
---
Flash Point
> 163.00 °C (> 325.4 °F) Cleveland open cup
Freezing Point
---
Properties Status
---
Relative Evaporation Rate
---
Explosive Limits
---
Upper Explosive Limit
Not available.
Voc Content
Not available.
Melting Point
Not available.
Metal Corrosion
---
Evaporation Rate
Not determined
Odor
Negligible
Partition Coefficient
Not determined
Ph
Not applicable
Decomposition Temperature
Not available.
Solubility In Water
Insoluble
Vapor Density
Not available.
Kinematic Viscosity
Not available.
Lower Explosive Limit
Not available.
Auto Ignition Temperature
Not applicable
Flammability
Not applicable
Crystallisation Point
---
Dynamic Viscosity
Not available.
State Under Standard Conditions
---
Colour
Colorless
Physical State
Solid
Solubility
---
Bulk Density
---
Form
---
Softening Point
---
Density
---
Colour Intensity
---
Relative Density
1.0 - 1.1
Boiling Point
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Avoid moisture. Prolonged heating at temperatures above 150 °C.

Incompatible

Reacts with water: generation of heat.

Decomposition

Upon decomposition, this product may yield gaseous nitrogen oxides, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Hydrogen cyanide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT PUR 9022 known as PURMELT QR 9022?

The signal word is danger.

What is the physical form of TECHNOMELT PUR 9022 known as PURMELT QR 9022?

TECHNOMELT PUR 9022 known as PURMELT QR 9022 is a solid with colorless color. It has negligible odor.

What is TECHNOMELT PUR 9022 known as PURMELT QR 9022 used for?

Urethane adhesive

What are the hazard statements for TECHNOMELT PUR 9022 known as PURMELT QR 9022?

This substance has 8 hazard statements:

  • H242: STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
  • H335: VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
  • H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
  • MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.

What is the melting point of TECHNOMELT PUR 9022 known as PURMELT QR 9022?

The melting point is Not available. and the boiling point is Not available..