Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT PUR 9022 known as PURMELT QR 9022
- Product Code
- 1217909
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Urethane adhesive
Uses advised against
This product is for industrial use only.
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Poly[oxy(methyl-1,2-ethanediyl)], a-hydro-w-hydroxy-, polymer with Dynacoll RP 360 and 1,1'-Methylenebis[4-isocyanatobenzene] | --- | 80 - 100% | Yes |
| Methylenebis(phenylisocyanate) | 101-68-8 | 1 - 5% | Yes |
| o-(p-Isocyanatobenzyl)phenyl isocyanate | 5873-54-1 | 0.1 - 1% | Yes |
| Methyl methacrylate | 80-62-6 | 0.1 - 1% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion. If breathing is difficult, give oxygen.
Cover affected areas with clean sheeting or gauze and seek immediate medical attention. Cool melted product on skin with plenty of water. Do not remove solidified product. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.
Symptoms: Molten adhesive may cause severe burns.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
If material is ingested, immediately contact a physician or poison control center.
Immediate Medical Attention
Cover affected areas with clean sheeting or gauze and seek immediate medical attention. Seek medical attention (for eye contact). If material is ingested, immediately contact a physician or poison control center.
Medical Treatment
Persons with asthmatic-type conditions, chronic bronchitis, other chronic respiratory diseases or recurrent skin eczema or sensitization should be excluded from working with isocyanates.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel.
No special environmental precautions required. Do not allow material to contaminate ground water system.
If product is spilled in the solid state, pick up and place in an appropriate waste disposal container. If product is spilled in the molten state, allow product to solidify before scraping up and disposing of in an appropriate waste disposal container.
Related Products
Similar products with comparable safety profiles
TECHNOMELT PUR 798A KNOWN AS PURMELT QR 798A
---
TECHNOMELT PUR 149C known as PURMELT QR 149C
---
TECHNOMELT PUR 913A known as PURMELT QR 913A
---
TECHNOMELT PUR 631B known as PURMELT QR 631B
---
TECHNOMELT PUR 2579 KNOWN AS PURMELT QR 2579
---
TECHNOMELT PUR 4663 known as Purmelt QR 4663
---
TECHNOMELT PUR 3317 BR known as Purmelt QR 3317 BR
---
TECHNOMELT PUR 170-7310 known as Purmelt QR 170-7310 DRM180KG
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
This product should only be heated to recommended temperatures. Hazards of pyrolysis products emitted are unknown and may be hazardous to health. If recommended temperature is exceeded, there is an increased possibility that MDI may be released. Equipment should be closely monitored. Always be careful around molten material. Follow suggested application temperature. Avoid skin contact with molten resins. Use caution if using container unloading equipment that inverts product, in order to avoid dislodging product prematurely.
Store between -20 °C (-4°F) and 50 °C (122°F). Avoid moisture. Store at room temperature. Keep container closed. Do not let moisture contaminate this material. Do not reseal if moisture contamination is suspected.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Will not occur.
Avoid moisture. Prolonged heating at temperatures above 150 °C.
Reacts with water: generation of heat.
Upon decomposition, this product may yield gaseous nitrogen oxides, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Hydrogen cyanide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT PUR 9022 known as PURMELT QR 9022?
The signal word is danger.
What is the physical form of TECHNOMELT PUR 9022 known as PURMELT QR 9022?
TECHNOMELT PUR 9022 known as PURMELT QR 9022 is a solid with colorless color. It has negligible odor.
What is TECHNOMELT PUR 9022 known as PURMELT QR 9022 used for?
Urethane adhesive
What are the hazard statements for TECHNOMELT PUR 9022 known as PURMELT QR 9022?
This substance has 8 hazard statements:
- H242: STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H335: VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
- MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.