NextSDS Logo
Safety Data Sheet EN

Methylene blue alkalic solution acc. Loeffler

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Methylene blue alkalic solution acc. Loeffler
Product Code
CL04.1302

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

C

CHEM-LAB NV

manufacturer

Industriezone "De Arend" 2, B-8210 ZEDELGEM - BELGIUM

(32)-50-288320

C

CHEM-LAB NV

Emergency Contacts

Emergency Contact

00 (32) 50.28.83.20

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Formula: KOH/C2H5OH/C16H18ClN3S/H2O

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Fresh air.

Skin contact

Wash off with plenty of water. Remove contaminated clothing.

Eye contact

Rinse out with plenty of water with the eyelid held wide open.

Ingestion

Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most). Call in physician.

Immediate Medical Attention

Call in physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In adaption to materials stored in the immediate neighbourhood.

Unsuitable media

Prevent fire-fighting water from entering surface water or groundwater.

Specific hazards

Non-combustible. Ambient fire may liberate hazardous vapours.

Firefighter Protection

Do not stay in dangerous zone without self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not inhale vapours/aerosols. Avoid substance contact. Ensure supply of fresh air in enclosed rooms.

Environmental

Do not allow to enter sewerage system.

Cleanup methods

Absorb

Materials: vermiculite, sand or a pillow from Chemical Spill Center

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary. The product should be handled with the care usual when dealing with chemicals. For precautions see section 2.2

Storage

Tightly closed. Recommended storage temperature see product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1

Hands

Required.

Eyes

Required.

Respiratory

Required when vapours/aerosols/dust are generated. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Required.

Environmental

Do not allow to enter sewerage system.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid
Colour
blue
Colour Intensity
---
Form
Liquid
Odor
Odourless
Odor Threshold
---
Ph
---
Melting Point
0°C
Boiling Point
100°C
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,98 g/ml
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No further relevant information available.

Reactivity

See section 10.3

Hazardous reactions

Dangerous reactions are not expected handling the product according to its intended use.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No further relevant information available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Methylene blue alkalic solution acc. Loeffler?

The signal word is no signal word.

What is the physical form of Methylene blue alkalic solution acc. Loeffler?

Methylene blue alkalic solution acc. Loeffler is a liquid appearing as liquid with blue color. It has odourless odor.

What is Methylene blue alkalic solution acc. Loeffler used for?

Reagent for analysis

What is the melting point of Methylene blue alkalic solution acc. Loeffler?

The melting point is 0°C and the boiling point is 100°C.