NextSDS Logo
Safety Data Sheet EN

Methylene blue (C.I. 52015)

CAS 61-73-4
EC 200-515-2

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Methylene blue (C.I. 52015)
Product Code
A514
Chemical Name
Methylene blue
Synonyms
Basic blue 9

Regulatory Identifiers

CAS Number
61-73-4 Check regulations →
EC Number
200-515-2 Check regulations →
REACH No.
It is not required to list the identified uses because the substance is not subject to registration according to REACH (< 1 t/a).

Identified Uses

Laboratory chemical, Laboratory and analytical use

Uses advised against

Do not use for products which come into contact with foodstuffs. Do not use for private purposes (household).

Manufacturers & Suppliers

Carl Roth GmbH + Co KG logo

Carl Roth GmbH + Co KG

manufacturer

Schoemperlenstr. 3-5, D-76185 Karlsruhe, Germany

+49 (0) 721 - 56 06 0

https://www.carlroth.de

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H302 Harmful if swallowed

Precautionary Statements

P270 Do not eat, drink or smoke when using this product
P301 + P312 IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Methylene blue EC: 200-515-2 61-73-4 --- Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice.

Skin contact

Rinse skin with water/shower. In all cases of doubt, or when symptoms persist, seek medical advice.

Eye contact

Rinse cautiously with water for several minutes. In all cases of doubt, or when symptoms persist, seek medical advice.

Ingestion

Rinse mouth with water (only if the person is conscious). Call a doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

co-ordinate firefighting measures to the fire surroundings; water, foam, dry extinguishing powder, ABC-powder

Unsuitable media

water jet

Specific hazards

Combustible.

Instructions

Fight fire with normal precautions from a reasonable distance.

Firefighter Protection

In case of fire and/or explosion do not breathe fumes. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe dust. Avoid contact with skin and eyes.

Environmental

Keep away from drains, surface and ground water.

Cleanup methods

Take up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid dust formation.

Storage

Store in a dry place. Keep container tightly closed.

Hygiene

Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. The times are approximate values from measurements at 22 °C and permanent contact. Increased temperatures due to heated substances, body heat etc. and a reduction of the effective layer thickness by stretching can lead to a considerable reduction of the breakthrough time. If in doubt, contact manufacturer. At an approx. 1.5 times larger / smaller layer thickness, the respective breakthrough time is doubled / halved. The data apply only to the pure substance. When transferred to substance mixtures, they may only be considered as a guide. Type of material: NBR (Nitrile rubber). Material thickness: >0,11 mm. Breakthrough times of the glove material: >480 minutes (permeation: level 6).

Eyes

Use safety goggle with side protection.

Respiratory

Respiratory protection necessary at: Dust formation. Particulate filter device (EN 143). P2 (filters at least 94 % of airborne particles, colour code: White).

Skin/Body

Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended.

Environmental

Keep away from drains, surface and ground water.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
solid
Solidification Point
---
Ph
~ 3 (in aqueous solution: 10 g/l, 20 °C)
Boiling Point
not determined
Lower Explosive Limit
not determined
Upper Explosive Limit
not determined
Softening Point
---
Vapor Density
---
Bulk Density
400 – 600 kg/m³
Kinematic Viscosity
not relevant
Colour
dark green
Physical State
solid
Dynamic Viscosity
---
Cloud Point
---
Form
powder, crystalline
Solubility In Water
soluble
Evaporation Rate
---
Melting Point
180 – 190 °C
Odor
odourless
Odor Threshold
---
Auto Ignition Temperature
not determined
Solubility In Fat
---
Voc Content
---
Appearance
---
Solubility
---
Flash Point
not applicable
Relative Density
---
State Under Standard Conditions
---
Flammability
this material is combustible, but will not ignite readily
Freezing Point
---
Crystallisation Point
---
Explosive Limits
---
Vapor Pressure
not determined
Density
not determined
Partition Coefficient
this information is not available
Properties Status
---
Metal Corrosion
---
Colour Intensity
---
Decomposition Temperature
>190 °C
Relative Evaporation Rate
---
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

The product in the delivered form is not dust explosion capable; the enrichment of fine dust however leads to the danger of dust explosion.

Hazardous reactions

Violent reaction with: strong oxidiser

Avoid

Keep away from heat. Decomposition takes place from temperatures above: >190 °C.

Incompatible

There is no additional information.

Decomposition

Hazardous combustion products: see section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
not assigned
Packing Group
not assigned
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Methylene blue (C.I. 52015) known by?

Methylene blue (C.I. 52015) is also known as: Basic blue 9

What is the hazard signal word for Methylene blue (C.I. 52015)?

The signal word is warning.

What is the physical form of Methylene blue (C.I. 52015)?

Methylene blue (C.I. 52015) is a solid with dark green color. It has odourless odor.

What is Methylene blue (C.I. 52015) used for?

Laboratory chemical, Laboratory and analytical use

What are the hazard statements for Methylene blue (C.I. 52015)?

This substance has 1 hazard statement:

  • H302: Harmful if swallowed

What is the melting point of Methylene blue (C.I. 52015)?

The melting point is 180 – 190 °C and the boiling point is not determined.