NextSDS Logo
Safety Data Sheet EN

Silirub PC

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Silirub PC

Regulatory Identifiers

CAS Number
N/A
REACH No.
Not applicable (mixture)

Identified Uses

Sealant

Uses advised against

No uses advised against

Manufacturers & Suppliers

S

SOUDAL N.V.

national supplier

Everdongenlaan 18-20, B-2300 Turnhout

+32 14 42 42 31

S

SOUDAL N.V.

manufacturer

Everdongenlaan 18-20, B-2300 Turnhout

+32 14 42 42 31

Emergency Contacts

BIG

+32 14 58 45 45

24h/24h

EN, FR, DE, NL

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This mixture does not contain any notifiable substances

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Symptoms: No effects known.

Skin contact

Wash with water and soap. Take victim to a doctor if irritation persists.

Symptoms: No effects known.

Eye contact

Rinse with water. Take victim to an ophthalmologist if irritation persists.

Symptoms: No effects known.

Ingestion

Rinse mouth with water. Do not induce vomiting. Consult a doctor/medical service if you feel unwell.

Symptoms: AFTER INGESTION OF HIGH QUANTITIES: Nausea. Vomiting. Abdominal pain. Diarrhoea.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Polyvalent foam. ABC powder. Carbon dioxide.

Unsuitable media

No unsuitable extinguishing media known.

Specific hazards

On burning: release of toxic and corrosive gases/vapours (hydrogen chloride, carbon monoxide - carbon dioxide).

Instructions

Dilute toxic gases with water spray.

Firefighter Protection

Gloves. Protective clothing. Heat/fire exposure: compressed air/oxygen apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Contain leaking substance. Use appropriate containment to avoid environmental contamination.

Cleanup methods

Clean contaminated surfaces with a soap solution.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from naked flames/heat. Observe normal hygiene standards.

Storage

Meet the legal requirements.

Hygiene

Observe normal hygiene standards.

Fire prevention

Keep away from naked flames/heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Keep away from naked flames/heat. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.

Hands

Gloves.

Eyes

Safety glasses.

Respiratory

Respiratory protection not required in normal conditions.

Skin/Body

Protective clothing.

Environmental

See headings 6.2, 6.3 and 13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Paste
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Variable in colour, depending on the composition
Colour Intensity
---
Form
Paste
Odor
Characteristic odour
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
>161 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable
Vapor Pressure
No data available
Vapor Density
---
Relative Density
1
Bulk Density
---
Density
1025 kg/m³
Flammability
Not easily combustible
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
No data available
Partition Coefficient
Not applicable (mixture)
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Temperature above flashpoint: higher fire/explosion hazard. No data available.

Hazardous reactions

No data available.

Avoid

Keep away from naked flames/heat.

Incompatible

No data available.

Decomposition

On burning: release of toxic and corrosive gases/vapours (hydrogen chloride, carbon monoxide - carbon dioxide).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Silirub PC No (test)data on the mixture available Judgement of the mixture is based on the relevant ingredients Conclusion Not classified as dangerous for the environment according to the criteria of Regulation (EC) No 1272/2008

Not classified as dangerous for the environment according to the criteria of Regulation (EC) No 1272/2008

12.2. Persistence and degradability

Contains readily biodegradable component(s)

Contains readily biodegradable component(s)

12.3. Bioaccumulative potential

Silirub PC Log Kow | Method | Remark | Value | Temperature | Value determination | | --- | --- | --- | --- | --- | | | Not applicable (mixture) | | | | Conclusion Contains bioaccumulative component(s)

Contains bioaccumulative component(s)

12.4. Mobility in soil

No (test)data on mobility of the components available

12.5. Results of PBT and vPvB assessment

Does not contain component(s) that meet (s) the criteria of PBT and/or vPvB as listed in Annex XIII of Regulation (EC) No 1907/2006.

The substance does not meet the criteria for PBT or vPvB as defined in Annex XIII of Regulation (EC) No 1907/2006.

12.6. Other adverse effects

Silirub PC Global warming potential (GWP) None of the known components is included in the list of fluorinated greenhouse gases (Regulation (EC) No 517/2014) Ozone-depleting potential (ODP) Not classified as dangerous for the ozone layer (Regulation (EC) No 1005/2009)

The substance is not included in the list of fluorinated greenhouse gases and is not classified as dangerous for the ozone layer.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Remove waste in accordance with local and/or national regulations. Remove to an authorized waste treatment plant. Do not discharge into drains or the environment.

Disposal

Remove to an authorized waste treatment plant.

Waste Codes

08 04 10 wastes from MFSU of adhesives and sealants (including waterproofing products): waste adhesives and sealants other than those mentioned in 08 04 09 EWC
15 01 02 plastic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Silirub PC?

The signal word is no signal word.

What is the physical form of Silirub PC?

Silirub PC is a paste with variable in colour, depending on the composition color. It has characteristic odour odor.

What is the solubility of Silirub PC?

No data available

What is Silirub PC used for?

Sealant

What is the melting point of Silirub PC?

The melting point is No data available and the boiling point is No data available.