Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Jotamastic 90 Comp A
- Product Form
- Liquid
- Product Code
- 16560
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Use in coatings - Industrial use Use in coatings - Professional use
Manufacturers & Suppliers
Jotun A/S
manufacturer
P.O. Box 2021, 3202 Sandefjord, Norway
+47 33 45 70 00
Jotun Paints (Europe) Ltd.
manufacturer
Stather Road Flixborough, Scunthorpe North, Lincolnshire DN15 8RR, England
+44 1724 400 000
Jotun Norway
manufacturer
+47 33 45 70 00
Emergency Contacts
NHS Direct
0845 4647
24/7
NHS Direct
111
24/7
Jotun Norway (head office)
+47 33 45 70 00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| epoxy resin (MW ≤ 700) EC: 216-823-5 | 1675-54-3 | 20% | Yes |
| talc (non-asbestos form) EC: 238-877-9 | 14807-96-6 | 25% | No |
| xylene EC: 215-535-7 | 1330-20-7 | 10% | Yes |
| Phenol, methylstyrenated EC: 700-960-7 | 68512-30-1 | 10% | Yes |
| 4,4'-Isopropylidenediphenol, oligomeric reaction products with 1-chloro-2,3-epoxypropane, reaction products with fatty acids, C18-unsatd., dimers EC: 500-180-5 | 67989-52-0 | 4.7% | Yes |
| 2-methylpropan-1-ol EC: 201-148-0 | 78-83-1 | 5% | Yes |
| glycidyl ether of 3-alkyl phenol EC: 500-210-7 | 68413-24-1 | 5% | Yes |
| benzyl alcohol EC: 202-859-9 | 100-51-6 | 3% | Yes |
| ethylbenzene EC: 202-849-4 | 100-41-4 | 3% | Yes |
| titanium dioxide EC: 236-675-5 | 13463-67-7 | 3% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: No specific data.
Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Chemical burns must be treated promptly by a physician. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: Adverse symptoms may include the following: pain or irritation, redness, blistering may occur
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Chemical burns must be treated promptly by a physician.
Symptoms: Adverse symptoms may include the following: pain, watering, redness
Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Chemical burns must be treated promptly by a physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: Adverse symptoms may include the following: stomach pains
Immediate Medical Attention
Get medical attention immediately. Call a poison center or physician.
Medical Treatment
Chemical burns must be treated promptly by a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Recommended: alcohol-resistant foam, CO₂, powders, water spray.
Do not use water jet.
Flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. This material is harmful to aquatic life with long lasting effects.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to British standard BS EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Water polluting material. May be harmful to the environment if released in large quantities.
Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Jotamastic 90 Standard Comp B
---
Jotacote Universal Comp A
---
Resist 86 Comp A
---
TASKI Jontec 300 QS F4c
UFI: 1EK6-W007-V007-P6XD
Grafit FGK 96 A
CAS: 999999-99-4
TASKI Jontec OmniStrip F1e
UFI: FYP5-X046-U00U-0YFR
TASKI Jontec OmniStrip F1e
UFI: FYP5-X046-U00U-0YFR
Caromax 20HN
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent the creation of flammable or explosive concentrations of vapours in air and avoid vapour concentrations higher than the occupational exposure limits. Avoid contact with skin and eyes. Avoid the inhalation of dust, particulates, spray or mist arising from the application of this mixture. Put on appropriate personal protective equipment. Never use pressure to empty. Keep in original container.
Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store away from heat, sparks, open flame or any other ignition source.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Keep away from heat, sparks and flame. No sparking tools should be used. Always use earthing leads when transferring from one container to another.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
There is no one glove material or combination of materials that will give unlimited resistance to any individual or combination of chemicals. The breakthrough time must be greater than the end use time of the product. The instructions and information provided by the glove manufacturer on use, storage, maintenance and replacement must be followed. Gloves should be replaced regularly and if there is any sign of damage to the glove material. Always ensure that gloves are free from defects and that they are stored and used correctly. The performance or effectiveness of the glove may be reduced by physical/chemical damage and poor maintenance. Barrier creams may help to protect the exposed areas of the skin but should not be applied once exposure has occurred. Wear suitable gloves tested to EN 374. Recommended, gloves(breakthrough time) > 8 hours: Viton® (> 0.7 mm), nitrile rubber (> 0.75 mm), 4H/Silver Shield® (> 0.07 mm), Teflon (> 0.35 mm) Not recommended, gloves(breakthrough time) < 1 hour: PVC (> 0.5 mm) May be used, gloves(breakthrough time) 4 - 8 hours: neoprene (> 0.35 mm), butyl rubber (> 0.4 mm), polyvinyl alcohol (PVA) (> 0.3 mm) For right choice of glove materials, with focus on chemical resistance and time of penetration, seek advice by the supplier of chemical resistant gloves. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.
Safety eyewear complying to EN 166 should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles and/or face shield. If inhalation hazards exist, a full-face respirator may be required instead.
If workers are exposed to concentrations above the exposure limit, they must use a respirator according to EN 140. Use respiratory mask with charcoal and dust filter when spraying this product, according to EN 14387 (as filter combination A2-P2). In confined spaces, use compressed-air or fresh-air respiratory equipment. When use of roller or brush, consider use of charcoal filter.
Use chemical-resistant protective suit / disposable overall. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to British Standard BS EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Do not allow to enter drains or watercourses.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
When exposed to high temperatures
Keep away from the following materials to prevent strong exothermic reactions: oxidising agents, strong alkalis, strong acids.
hazardous decomposition products
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- Paint
- Transport Class
- 3
- Packing Group
- III
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Jotamastic 90 Comp A?
The signal word is danger.
What is the physical form of Jotamastic 90 Comp A?
Jotamastic 90 Comp A is a liquid. with black, white. grey. red. green. yellow. blue. color. It has characteristic. odor.
What is Jotamastic 90 Comp A used for?
Use in coatings - Industrial use Use in coatings - Professional use
What are the hazard statements for Jotamastic 90 Comp A?
This substance has 5 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Jotamastic 90 Comp A?
The melting point is Not applicable. and the boiling point is Not available..