NextSDS Logo
Safety Data Sheet EN

Methylene blue (C.I.52015) for microscopy Certistain®

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Methylene blue (C.I.52015) for microscopy Certistain®
Product Code
115943

Regulatory Identifiers

CAS Number
N/A
REACH No.
A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

In vitro diagnostic reagent, Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merckgroup.com).

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H302 Harmful if swallowed.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Methylene blue EC: 200-515-2 61-73-4 50 - 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

immediately make victim drink water (two glasses at most).

Immediate Medical Attention

Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.

Hands

full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min; splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet<(>,<)> supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Safety glasses

Respiratory

required when dusts are generated. Recommended Filter type: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
No information available.
State Under Standard Conditions
---
Upper Explosive Limit
No information available.
Boiling Point
No information available.
Solidification Point
---
Cloud Point
---
Relative Evaporation Rate
---
Crystallisation Point
---
Molecular Weight
---
Colour
dark blue
Metal Corrosion
---
Form
solid
Physical State
solid
Appearance
dark blue
Vapor Pressure
No information available.
Odor Threshold
Not applicable
Ph
ca. 3 at 10 g/l 20 °C
Decomposition Temperature
No information available.
Explosive Limits
---
Flash Point
No information available.
Solubility In Fat
---
Lower Explosive Limit
No information available.
Partition Coefficient
log Pow: 5,85 (calculated) (Lit.)
Solubility In Water
ca.50 g/l at 20 °C
Relative Density
No information available.
Physical State Data
solid
Melting Point
ca. 180 °C (decomposition)
Dynamic Viscosity
No information available.
Auto Ignition Temperature
No information available.
Bulk Density
ca.400 - 600 kg/m3
Softening Point
---
Freezing Point
---
Voc Content
---
Odor
odourless
Kinematic Viscosity
---
Solubility
---
Evaporation Rate
No information available.
Colour Intensity
---
Properties Status
---
Density
No information available.
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature) .

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents, Bases, Reducing agents, alkali compounds, iodides, potassium dichromate

Avoid

Strong heating (decomposition).

Incompatible

no information available

Decomposition

in the event of fire: See section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Methylene blue (C.I.52015) for microscopy Certistain®?

The signal word is warning.

What is the physical form of Methylene blue (C.I.52015) for microscopy Certistain®?

Methylene blue (C.I.52015) for microscopy Certistain® is a solid appearing as dark blue with dark blue color. It has odourless odor.

What is Methylene blue (C.I.52015) for microscopy Certistain® used for?

In vitro diagnostic reagent, Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merckgroup.com).

What are the hazard statements for Methylene blue (C.I.52015) for microscopy Certistain®?

This substance has 1 hazard statement:

  • H302: Harmful if swallowed.

What is the melting point of Methylene blue (C.I.52015) for microscopy Certistain®?

The melting point is ca. 180 °C (decomposition) and the boiling point is No information available..