Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- n-Hexadecane
- Product Code
- A10322
- Chemical Name
- n-Hexadecane
- Synonyms
- N-Cetane; Cetane; N-Hexadecane.
Regulatory Identifiers
- CAS Number
- 544-76-3 Check regulations →
- EC Number
- 208-878-9 Check regulations →
Identified Uses
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
Uses advised against
No Information available
Manufacturers & Suppliers
Alfa Aesar, Avocado Research Chemicals, Ltd.
manufacturer
Shore Road, Port of Heysham Industrial Park, Heysham, Lancashire LA3 2XY, United Kingdom
+44 (0) 1524 850506
http://www.alfa.com
Emergency Contacts
Carechem 24
+44 (0) 1865 407333
EN
Carechem 24
+44 (0) 1235 239670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hexadecane EC: 208-878-9 | 544-76-3 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Symptoms: Risk of serious damage to the lungs (by aspiration).
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Do NOT induce vomiting. Call a physician or poison control center immediately. If vomiting occurs naturally, have victim lean forward.
Immediate Medical Attention
Get medical attention if symptoms occur or persist. Call a physician or poison control center immediately for ingestion.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Ensure adequate ventilation.
Should not be released into the environment.
Soak up with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid ingestion and inhalation. Do not get in eyes, on skin, or on clothing.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Viton (R). Breakthrough time: See manufacturers recommendations. Glove thickness: -. EU standard: EN 374. Glove comments: (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Organic gases and vapours filter Type A Brown conforming to EN14387. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141
Long sleeved clothing
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous Polymerization: No information available.
Incompatible products. Excess heat.
Strong oxidizing agents.
Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is n-Hexadecane known by?
n-Hexadecane is also known as: N-Cetane; Cetane; N-Hexadecane.
What is the hazard signal word for n-Hexadecane?
The signal word is danger.
What is the physical form of n-Hexadecane?
n-Hexadecane is a liquid appearing as colorless . It has no information available odor.
What is n-Hexadecane used for?
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
What are the hazard statements for n-Hexadecane?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways
What is the melting point of n-Hexadecane?
The melting point is 18 °C / 64.4 °F and the boiling point is 287 °C / 548.6 °F.