Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- VANAL AERO
- Product Code
- 61100000
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Life cycle stages: PW Widespread use by professional workers, IS Use at industrial Sites. Sector of Use: SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen). Product category: PC9a Coatings and paints, thinners, paint removers. Process category: PROC7 Industrial spraying, PROC11 Non industrial spraying. Application of the substance / the mixture: Lubricant
Manufacturers & Suppliers
ZEP ITALIA SRL
manufacturer
Piazzale Luigi Cadorna, 2, 20123 Milano (MI) - Italy; Via Nettunense Km. 25.000, 04011 Aprilia (LT) - Italy
+39.06.926691
http://www.zep.it
ZEP Industries BV
manufacturer
Vierlinghweg 30, 4612 PN Bergen op Zoom, The Netherlands
+ 31 164 250 100
ZEP UK Ltd
distributor
Tanhouse Lane, Widnes Cheshire, WA8 0RD, United Kingdom
+44 (0)151 422 1000
http://www.zep.co.uk
Emergency Contacts
NHS
+44 0845 46 47
NHS
+44 08454 24 24 24
Emergency Contact
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C6, isoalkanes, <5% n-hexane EC: 931-254-9 | --- | 75 - 100% | Yes |
| aluminium powder (stabilised) EC: 231-072-3 | 7429-90-5 | 5 - 10% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 2.5 - 5% | Yes |
| n-hexane EC: 203-777-6 | 110-54-3 | 0.25 - 1% | Yes |
| 2,6-di-tert-butyl-p-cresol EC: 204-881-4 | 128-37-0 | 0.25 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
If skin irritation continues, consult a doctor.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. Protect unharmed eye.
Seek immediate medical advice.
Immediate Medical Attention
Seek immediate medical advice.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Do not inhale explosion gases or combustion gases.
Cool endangered receptacles with water spray.
Firefighter Protection
Wear fully protective suit. Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric lights. Do not pierce or burn, even after use.
Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended. Not suitable are gloves made of the following materials: Strong material gloves
Use suitable respiratory protective device only when aerosol or mist is formed.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow 'separated from' class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for VANAL AERO?
The signal word is danger.
What is the physical form of VANAL AERO?
VANAL AERO is a aerosol with silver-coloured color. It has characteristic odor.
What is VANAL AERO used for?
Life cycle stages: PW Widespread use by professional workers, IS Use at industrial Sites. Sector of Use: SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen). Product category: PC9a Coatings and paints, thinners, paint removers. Process category: PROC7 Industrial spraying, PROC11 Non industrial spraying. Application of the substance / the mixture: Lubricant
What are the hazard statements for VANAL AERO?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of VANAL AERO?
The melting point is Undetermined. and the boiling point is 69 °C.