Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- METALUBE COOL FLUID AERO
- Product Code
- 06630001
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- F6H7-M05K-W000-888T
Identified Uses
Life cycle stages PW Widespread use by professional workers; Sector of Use SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen); Product category PC24 Lubricants, greases, release products; Process category PROC19 Manual activities involving hand contact, PROC7 Industrial spraying, PROC11 Non industrial spraying; Application of the substance / the mixture Coolant/ Cutting solution
Manufacturers & Suppliers
ZEP ITALIA SRL
manufacturer
Piazzale Luigi Cadorna, 2, 20123 Milano (MI) - Italy; Via Nettunense Km. 25.000, 04011 Aprilia (LT) - Italy
+39.06.926691
http://www.zep.it
ZEP Industries BV
manufacturer
Vierlinghweg 30, 4612 PN Bergen op Zoom, The Netherlands
+ 31 164 250 100
ZEP UK Ltd
distributor
Tanhouse Lane, Widnes Cheshire, WA8 0RD, United Kingdom
+44 (0)151 422 1000
http://www.zep.co.uk
Emergency Contacts
NHS
+44 0845 46 47
NHS
+44 08454 24 24 24
emergency number (europe)
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Active substance with propellant
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| propan-2-ol EC: 200-661-7 | 67-63-0 | 25 - 50% | Yes |
| butane (< 0.1% butadine) EC: 203-448-7 | 106-97-8 | 25 - 50% | Yes |
| Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 | 64742-55-8 | 10 - 25% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 5 - 10% | Yes |
| isobutane (<0.1% butadine) EC: 200-857-2 | 75-28-5 | 1 - 2.5% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. In case of unconsciousness place patient stably in side position for transportation.
If skin irritation continues, consult a doctor. Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Seek immediate medical advice.
Immediate Medical Attention
Seek immediate medical advice.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
Formation of toxic gases is possible during heating or in case of fire.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away. Remove persons from danger area.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric lights. Do not pierce or burn, even after use.
Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Recommended thickness of the material: ≥ 0.5 mm. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended. Not suitable are gloves made of the following materials: Strong material gloves
Tightly sealed goggles
Use suitable respiratory protective device in case of insufficient ventilation. Use suitable respiratory protective device only when aerosol or mist is formed. Filter AX/P2
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for METALUBE COOL FLUID AERO?
The signal word is danger.
What is the physical form of METALUBE COOL FLUID AERO?
METALUBE COOL FLUID AERO is a aerosol with light yellow color. It has characteristic odor.
What is METALUBE COOL FLUID AERO used for?
Life cycle stages PW Widespread use by professional workers; Sector of Use SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen); Product category PC24 Lubricants, greases, release products; Process category PROC19 Manual activities involving hand contact, PROC7 Industrial spraying, PROC11 Non industrial spraying; Application of the substance / the mixture Coolant/ Cutting solution
What are the hazard statements for METALUBE COOL FLUID AERO?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of METALUBE COOL FLUID AERO?
The melting point is Undetermined. and the boiling point is -44 °C.