NextSDS Logo
Safety Data Sheet EN

Agar-agar technical for microbiology

CAS 9002-18-0

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Agar-agar technical for microbiology
Product Code
111925

Regulatory Identifiers

CAS Number
9002-18-0 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Biochemical research/analysis

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemical nature Base material for culture media.

Chemical Name CAS Number Concentration Hazardous
Agar-agar technical for microbiology EC: 232-658-1 --- --- No

For the full text of the H-Statements mentioned in this Section, see Section 16. The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com

Notes

Remarks No disclosure requirement according to Regulation (EC) No. 1907/2006.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

wash off with plenty of water. Remove contaminated clothing.

Eye contact

rinse out with plenty of water.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Symptoms: Diarrhoea

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Carbon dioxide (CO2), Foam, Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

No special precautionary measures necessary.

Cleanup methods

Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0,11 mm Break through time: > 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types.

Eyes

Safety glasses

Respiratory

required when dusts are generated. Empfohlener Filtertyp: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

No special precautionary measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Evaporation Rate
No information available.
Cloud Point
---
Physical State
solid
Voc Content
---
Bulk Density
ca.550 kg/m³
Auto Ignition Temperature
No information available.
Form
solid
Solidification Point
---
Appearance
---
Odor
odourless
Partition Coefficient
No information available.
State Under Standard Conditions
---
Melting Point
90 °C
Decomposition Temperature
No information available.
Kinematic Viscosity
---
Flammability
No information available.
Solubility In Water
20 g/l
Upper Explosive Limit
No information available.
Density
---
Dynamic Viscosity
No information available.
Solubility
---
Vapor Pressure
No information available.
Vapor Density
---
Flash Point
No information available.
Colour
beige
Softening Point
---
Relative Density
No information available.
Ph
6,8
Freezing Point
---
Odor Threshold
not applicable
Solubility In Fat
---
Crystallisation Point
---
Properties Status
---
Relative Evaporation Rate
---
Explosive Limits
---
Colour Intensity
---
Molecular Weight
---
Lower Explosive Limit
No information available.
Physical State Data
solid
Boiling Point
No information available.
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

no information available

Avoid

no information available

Incompatible

no information available

Decomposition

no information available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Agar-agar technical for microbiology?

The signal word is no signal word.

What is the physical form of Agar-agar technical for microbiology?

Agar-agar technical for microbiology is a solid with beige color. It has odourless odor.

What is Agar-agar technical for microbiology used for?

Biochemical research/analysis

What is the melting point of Agar-agar technical for microbiology?

The melting point is 90 °C and the boiling point is No information available..