Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR®
- Product Code
- 25851
- Synonyms
- Nickel dichloride hexahydrate
Regulatory Identifiers
- CAS Number
- 7791-20-0 Check regulations →
- REACH No.
- Not yet communicated down the supply chain.
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
distributor
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
VWR
BDH CHEMICALS
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Nickel (II) chloride hexahydrate | 7791-20-0 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately call a POISON CENTRE/doctor. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. In case of skin reactions, consult a physician.
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTRE/doctor. Do NOT induce vomiting. Rinse mouth thoroughly with water. Give nothing to eat or drink.
Immediate Medical Attention
Immediately call a POISON CENTRE/doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product itself does not burn. Co-ordinate fire-fighting measures to the fire surroundings.
no restriction
In case of fire may be liberated: Hydrogen chloride (HCl)
DO NOT fight fire when fire reaches explosives.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Clear spills immediately.
Do not allow to enter into surface water or drains.
Clean contaminated articles and floor according to the environmental legislation.
Related Products
Similar products with comparable safety profiles
Iron (III) chloride hexahydrate AnalaR NORMAPUR® ACS, Reag. Ph. Eur. analytical reagent
CAS: 10025-77-1
Ammonium thiocyanate AnalaR NORMAPUR® Reag. Ph. Eur. analytical reagent
CAS: 1762-95-4
Ammonium iron (II) sulphate hexahydrate AnalaR NORMAPUR®
CAS: 7783-85-9
Ammonium iron (II) sulphate hexahydrate AnalaR NORMAPUR®
CAS: 7783-85-9
Nickel(II) chloride, anhydrous
CAS: 7718-54-9
Cadmium (II) sulphate 8/3-hydrate AnalaR NORMAPUR® analytical reagent
CAS: 7790-84-3
Potassium Hydrogen Carbonate AnalaR NORMAPUR® Analytical Reagent
CAS: 298-14-6
Nickel(II) nitrate hexahydrate for analysis EMSURE® ACS
CAS: 13478-00-7
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation. Avoid contact with eyes and skin.
Keep container tightly closed and in a well-ventilated place. Store in a place accessible by authorized persons only.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms EN ISO 374. In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,12 mm, Breakthrough time: > 480 min, Recommended glove articles: VWR 112-0998. By long-term hand contact: Suitable material: NBR (Nitrile rubber), Thickness of the glove material: 0,38 mm, Breakthrough time: > 480 min, Recommended glove articles: VWR 112-3717 / 112-1381.
Eye glasses with side protection DIN-/EN-Norms: DIN EN 166. Recommendation: VWR 111-0432
Respiratory protection necessary at: aerosol or mist formation. Suitable respiratory protection apparatus: Filtering Half-face mask (DIN EN 149). Recommendation: VWR 111-0451. Suitable material: P3. Recommendation: VWR 111-0244
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
no data available
no data available
no data available
no data available
no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3288
- Shipping Name
- TOXIC SOLID, INORGANIC, N.O.S. (NICKEL (II) CHLORIDE HEXAHYDRATE)
- Transport Class
- 6.1
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR® known by?
Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR® is also known as: Nickel dichloride hexahydrate
What is the hazard signal word for Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR®?
The signal word is danger.
What is the physical form of Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR®?
Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR® is a solid with green color. It has no data available odor.
What is Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR® used for?
General chemical reagent
What are the hazard statements for Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR®?
This substance has 9 hazard statements:
- H301 + H331: Toxic if swallowed or if inhaled.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- H341: Suspected of causing genetic defects.
- H350i: May cause cancer by inhalation.
- H360D: May damage the unborn child.
- H372: Causes damage to organs through prolonged or repeated exposure.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Nickel (II) chloride hexahydrate AnalaR NORMAPUR® analytical reagent (max. 0.005% Co) AnalaR NORMAPUR®?
The melting point is 140 °C and the boiling point is no data available.