Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- OptiPhase HISafe 3
- Product Code
- 1200-437
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
PerkinElmer Health Sciences B.V.
manufacturer
Rigaveg 22, 9723 TH Groningen, The Netherlands; P.O. Box 5205, 9700 GE Groningen, The Netherlands
+31 50 5445900
http://www.perkinelmer.com
PerkinElmer
national supplier
Lvl 2, Bldg 5, Brandon Office Park, 530-540 Springvale Road, Glen Waverley, Melbourne, VIC 3150, Australia
+61 3-9212-8500
Emergency Contacts
Emergency Contact
+31 50 5445971
CHEMTREC
+(61)-290372994
CHEMTREC
+1 703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Diisopropyl naphthalene isomers | 38640-62-9 | 40 - 60% | Yes |
| Alkylphenol Polyglycolether | 9016-45-9 | 20 - 40% | Yes |
| 2-(2-butoxyethoxy)ethanol | 112-34-5 | 10 - 20% | Yes |
| Phenol, ethoxylated, phosphated, diethanolamine salt | 72283-39-7 | 2.5 - 10% | Yes |
| 2,5-Diphenyloxazole (PPO) | 92-71-7 | 2.5% | No |
| 1,4-Bis-(2-methylstyryl)-benzene (bis-MSB) | 13280-61-0 | 2.5% | No |
| water, distilled, conductivity or of similar purity | --- | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Rinse out mouth and then drink plenty of water. Do not induce vomiting: call for medical help immediately.
Immediate Medical Attention
call for medical help immediately
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, Fire-extinguishing powder, Carbon dioxide
Carbon monoxide (CO)
Firefighter Protection
Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace.
Protect from heat and direct sunlight.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
Not required.
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Diisopropyl naphthalene isomers, Alkylphenol Polyglycolether)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for OptiPhase HISafe 3?
The signal word is danger.
What is the physical form of OptiPhase HISafe 3?
OptiPhase HISafe 3 is a liquid with colourless color. It has characteristic odor.
What is OptiPhase HISafe 3 used for?
Laboratory chemicals
What are the hazard statements for OptiPhase HISafe 3?
This substance has 4 hazard statements:
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H410: Very toxic to aquatic life with long lasting effects.