NextSDS Logo
Safety Data Sheet EN

D-Mannitol

CAS 69-65-8

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
D-Mannitol
Product Code
63559
Chemical Name
D-Mannitol

Regulatory Identifiers

CAS Number
69-65-8 Check regulations →

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma

manufacturer

S

Sigma-Aldrich BVBA/SPRL

distributor

Pegasuslaan 5, B-1831 DIEGEM

+32 3 899 1301

Emergency Contacts

Emergency Contact

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Mannite --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration.

Skin contact

Wash off with soap and plenty of water.

Eye contact

Flush eyes with water as a precaution.

Ingestion

Never give anything by mouth to an unconscious person. Rinse mouth with water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific hazards

Carbon oxides

Firefighter Protection

Wear self contained breathing apparatus for fire fighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid dust formation. Avoid breathing vapors, mist or gas.

Environmental

Do not let product enter drains.

Cleanup methods

Sweep up and shovel.

Materials: suitable, closed containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide appropriate exhaust ventilation at places where dust is formed. Normal measures for preventive fire protection.

Storage

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

General industrial hygiene practice.

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Immersion protection: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: > 480 min, Material tested:Dermatril® (Aldrich Z677272, Size M). Splash protection: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: > 30 min, Material tested:Dermatril® (Aldrich Z677272, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 873000, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an Industrial Hygienist familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
---
Softening Point
---
Metal Corrosion
---
Relative Evaporation Rate
---
Properties Status
---
State Under Standard Conditions
---
Solubility In Fat
---
Colour
white
Crystallisation Point
---
Melting Point
166 - 168 °C
Flash Point
no data available
Colour Intensity
---
Physical State
solid
Solidification Point
---
Cloud Point
---
Lower Explosive Limit
---
Odor Threshold
no data available
Odor
no data available
Auto Ignition Temperature
no data available
Boiling Point
no data available
Evaporation Rate
---
Form
powder
Solubility In Water
182 g/l at 20 °C - completely soluble
Vapor Density
---
Ph
5,0 - 6,5 at 182 g/l at 25 °C
Density
---
Kinematic Viscosity
no data available
Voc Content
---
Upper Explosive Limit
---
Explosive Limits
---
Solubility
---
Freezing Point
---
Molecular Weight
---
Flammability
---
Appearance
powder, white
Physical State Data
solid
Decomposition Temperature
no data available
Partition Coefficient
---
Relative Density
no data available
Bulk Density
---
Dynamic Viscosity
no data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

no data available

Reactivity

no data available

Hazardous reactions

no data available

Avoid

no data available

Incompatible

Strong oxidizing agents

Decomposition

Other decomposition products - no data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for D-Mannitol?

The signal word is no signal word.

What is the physical form of D-Mannitol?

D-Mannitol is a solid appearing as powder, white with white color. It has no data available odor.

What is D-Mannitol used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of D-Mannitol?

The melting point is 166 - 168 °C and the boiling point is no data available.