Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 300 ML BONARIA LAVENDER AIRFRESHENER.
- Product Code
- 57362
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
MAC BRIDE
manufacturer
Z.I. de DIOULAN.29140.ROSPORDEN.FRANCE.
02 98 66 95 00
Emergency Contacts
Emergency Contact
01 45 42 59 59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| PROPANE EC: 200-827-9 | 74-98-6 | 2.5 - 10% | Yes |
| BUTANE AND ISOBUTANE EC: 203-448-7 | 106-97-8 | 25 - 50% | Yes |
| NAPHTHA ( PETROLEUM ), HYDROTREATED HEAVY EC: 265-150-3 | 64742-48-9 | 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If a large quantity is inhaled, move the patient into the fresh air and keep him/her warm and still.
Remove contaminated clothing and wash the skin thoroughly with soap and water or a recognised cleaner.
Wash thoroughly with soft, clean water for 15 minutes holding the eyelids open.
Symptoms: redness, pain or visual impairment
In the event of swallowing, if the quantity is small (no more than one mouthful), rinse the mouth with water and consult a doctor. If swallowed accidentally, call a doctor to assess the need for monitoring and subsequent treatment in hospital. Show him the label.
Immediate Medical Attention
Refer the patient to an ophthalmologist, in particular if there is any redness, pain or visual impairment. If swallowed accidentally, call a doctor to assess the need for monitoring and subsequent treatment in hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, chemical powders, foams, and other extinguishing gases.
Never use water.
pressurised containers from bursting
Keep packages near the fire cool, to prevent pressurised containers from bursting.
Firefighter Protection
Fire-fighting personnel are to be equipped with autonomous insulating breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Eliminate any possible source of ignition and ventilate the premises. Avoid inhaling the fumes. Consult the safety measures listed under headings 7 and 8.
Prevent any material from entering drains or waterways.
Clean preferably with a detergent, do not use solvents.
Related Products
Similar products with comparable safety profiles
300 ML BONARIA AIRFRESHENER LAVENDER AEROSOL
---
300 ML BONARIA AIRFRESHENER FLOWERS AEROSOL
---
Charm Air Freshener 240ml, All variants.
---
CHARM AIR FRESHENER AROMA ROSE 240ML
---
Charm Air Fresheners 240ml, All variants, (Compressed Air)
---
MOTIP 'ONE SHOT' AIR REFRESHER CITRUS 600 ML
---
MOTIP AIRCO CLEANER 500 ML
---
NOVALUBE AEROSOL 400ml
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in well-ventilated areas. Prevent the formation of flammable or explosive concentrations in air and avoid vapour concentrations higher than the occupational exposure limits. Do not spray on a naked flame or any incandescent material. Avoid inhaling fumes.
Keep the container tightly closed in a dry, well-ventilated place. Keep away from all sources of ignition - do not smoke. Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C. Keep out of reach of children.
Smoking, eating and drinking are prohibited in premises where the preparation is used.
Use the product in premises where there are no naked flames or other sources of ignition and have protected electrical equipment. Keep packages tightly closed and away from sources of heat, sparks and naked flames. Do not use tools which may produce sparks. Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, if possible with extractor fans at work posts and appropriate general extraction.
If this ventilation is insufficient to maintain the concentration of solvent fumes below the exposure limits, wear breathing apparatus
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Any apparatus likely to produce a flame or to have a metallic surface at high temperature (burners, electric arcs, furnaces etc.) must not be allowed on the premises.
carbon monoxide and dioxide, smoke and nitrogen oxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- Aerosols
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 300 ML BONARIA LAVENDER AIRFRESHENER.?
The signal word is no signal word.
What is the physical form of 300 ML BONARIA LAVENDER AIRFRESHENER.?
300 ML BONARIA LAVENDER AIRFRESHENER. is a fluid liquid .
What is the melting point of 300 ML BONARIA LAVENDER AIRFRESHENER.?
The melting point is not specified. and the boiling point is <= 35°C..