NextSDS Logo
Safety Data Sheet EN

Fixation and Permeabilization Solution

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Fixation and Permeabilization Solution
Product Code
51-2090KZ

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Sector of Use SU24 Scientific research and development, Product category PC21 Laboratory chemicals, Process category PROC1 Use in closed process, no likelihood of exposure, Environmental release category ERC7 Industrial use of substances in closed systems

Manufacturers & Suppliers

B

Becton Dickinson Biosciences Centralized European Office

manufacturer

Erembodegem-Dorp 86, 9320 Erembodegem, Belgium

+32 2 400 98 95

Emergency Contacts

Emergency Contact

+32 2 400 98 95

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Muta. Cat. 2 H341
Carc. Cat. 1A H350
Eye Dam. Cat. 1 H318
Acute Tox. Cat. 4 H332
Skin Irrit. Cat. 2 H315
Skin Sens. Cat. 1 H317
STOT SE Cat. 3 H335

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H318 Causes serious eye damage.
H332 Harmful if inhaled.
H335 May cause respiratory irritation.
H341 Suspected of causing genetic defects.
H350 May cause cancer. Route of exposure: Inhalative.

Precautionary Statements

P260 Do not breathe mist/vapours/spray.
P280 Wear protective clothing / eye protection.
P280 Wear protective gloves.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
formaldehyde EC: 200-001-8 --- 4.2% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient in side position for transportation.

Skin contact

immediately wash with water and soap and rinse thoroughly.

Eye contact

Flush immediately with water for 15 minutes, and consult a doctor.

Ingestion

Seek immediate medical advice.

Immediate Medical Attention

Seek immediate medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

The usual precautionary measures are to be adhered to when handling chemicals.

Environmental

No special measures required.

Cleanup methods

Absorb with liquid-binding material.

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Store in cool, dry conditions in well sealed receptacles.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation Material of gloves The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Odourless
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined
Boiling Point
100 °C
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
23 hPa
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,0024 g/cm3
Flammability
---
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Not miscible or difficult to mix
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No dangerous reactions known

Hazardous reactions

No dangerous reactions known

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Fixation and Permeabilization Solution?

The signal word is danger.

What is the physical form of Fixation and Permeabilization Solution?

Fixation and Permeabilization Solution is a liquid with colourless color. It has odourless odor.

What is Fixation and Permeabilization Solution used for?

Sector of Use SU24 Scientific research and development, Product category PC21 Laboratory chemicals, Process category PROC1 Use in closed process, no likelihood of exposure, Environmental release category ERC7 Industrial use of substances in closed systems

What are the hazard statements for Fixation and Permeabilization Solution?

This substance has 7 hazard statements:

  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H318: Causes serious eye damage.
  • H332: Harmful if inhaled.
  • H335: May cause respiratory irritation.
  • H341: Suspected of causing genetic defects.
  • H350: May cause cancer. Route of exposure: Inhalative.

What is the melting point of Fixation and Permeabilization Solution?

The melting point is Not determined and the boiling point is 100 °C.