Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Celite® 545
- Product Code
- 22140
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- 01-2119488518-22-XXXX
- UFI Code
- 5Y32-S6DE-F99D-VUXQ
Identified Uses
Laboratory chemicals, Manufacture of substances
Uses advised against
This product is not intended for consumer use.
Manufacturers & Suppliers
Merck Life Science BV/SRL
manufacturer
Brusselsesteenweg 288, B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Kieselguhr (contains free crystalline silicic acid) EC: 272-489-0 | 68855-54-9 | 90 - 100% | Yes |
| cristobalite EC: 238-455-4 | 14464-46-1 | 1 - 10% | Yes |
| Quartz, respirable EC: 238-878-4 | 14808-60-7 | 1 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
silicon oxides. Not combustible. Ambient fire may liberate hazardous vapours.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid generation and inhalation of dusts in all circumstances. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Filter aid, Celite® 503
CAS: 61790-53-2
CYMEL® 325 RESIN
UFI: 47V0-R0D0-D00D-HGP7
LOCTITE 545 BO50ML CH
---
CERECLOR™ S40/S45/S45SS/S50/S52/S52HV/S52SS/51L/S54/S55/S56/S58/S60/S63
CAS: 085535-85-9
CERECLOR™ S40/S45/S50 /S52/S52HV/ S52SS/51L/S54/S55/S56/S58/S60/S63
---
CERECLOR™ S40 / S45 / S50 / S52 / S52HV / S52SS / 51L / S54 / S55 / S56 / S58 / S60 / S63
---
HiTEC® 55450 Performance Additive
UFI: 8V7D-AGY7-1415-39DC
Aliquat® 336
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture.
Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M) data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2 The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
No data available
No data available
no information available
Strong acids, Hydrogen fluoride
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Celite® 545?
The signal word is danger.
What is the physical form of Celite® 545?
Celite® 545 is a powder with white color. It has no data available odor.
What is Celite® 545 used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for Celite® 545?
This substance has 1 hazard statement:
- H372: Causes damage to organs (Lungs) through prolonged or repeated exposure if inhaled.
What is the melting point of Celite® 545?
The melting point is No data available and the boiling point is No data available.