NextSDS Logo
Safety Data Sheet EN

Filter aid, Celite® 503

CAS 61790-53-2

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Filter aid, Celite® 503
Product Code
H30184

Regulatory Identifiers

CAS Number
61790-53-2 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar
Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street Ward Hill, MA 01835-8099

www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

During normal business hours (Monday-Friday, 8am-7pm EST)

Carechem 24

(866) 928-0789

After normal business hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Carc. Cat. 2 H351
Eye Irrit. Cat. 2A H319
STOT SE Cat. 3 H335

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H351 Suspected of causing cancer.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P281 Use personal protective equipment as required.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Celite 61790-53-2 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined.

Eyes

Safety glasses.

Respiratory

Use suitable respirator when high concentrations are present.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Vapor Pressure
Not applicable.
Dynamic Viscosity
Not applicable.
Vapor Density
Not applicable.
Solubility In Fat
---
Evaporation Rate
Not applicable.
Relative Density
Not determined.
Freezing Point
---
Lower Explosive Limit
Not determined
Appearance
Powder
Upper Explosive Limit
Not determined
Bulk Density
---
Colour Intensity
---
Kinematic Viscosity
Not applicable.
Explosive Limits
---
Melting Point
Not determined
Boiling Point
Not determined
Voc Content
---
Solubility In Water
Not determined
Odor Threshold
Not determined.
Solidification Point
---
Metal Corrosion
---
Softening Point
---
Partition Coefficient
Not determined.
Auto Ignition Temperature
Not determined
Properties Status
---
Form
Powder
Flammability
Not determined.
State Under Standard Conditions
---
Decomposition Temperature
Not determined
Flash Point
Not applicable
Solubility
Not determined
Cloud Point
---
Odor
Not determined
Density
Not determined
Colour
White
Crystallisation Point
---
Molecular Weight
---
Physical State Data
solid
Physical State
solid
Ph
Not applicable.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Filter aid, Celite® 503?

The signal word is warning.

What is the physical form of Filter aid, Celite® 503?

Filter aid, Celite® 503 is a solid appearing as powder with white color. It has not determined odor.

What is the solubility of Filter aid, Celite® 503?

Not determined

What is Filter aid, Celite® 503 used for?

SU24 Scientific research and development

What are the hazard statements for Filter aid, Celite® 503?

This substance has 3 hazard statements:

  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.
  • H351: Suspected of causing cancer.

What is the melting point of Filter aid, Celite® 503?

The melting point is Not determined and the boiling point is Not determined.

Compliance Scanner

Scan your compliance