Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Compressed air
- Product Code
- EIGA000A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial and professional uses. Perform risk assessment prior to use. Test gas/Calibration gas. Purge gas, diluting gas, inerting gas. Consumer use. Perform risk assessment prior to use. Breathing gas. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.
Uses advised against
None.
Manufacturers & Suppliers
AIR LIQUIDE BV
national supplier
De Witbogt 1, 5652 AG Eindhoven, the Netherlands
L'AIR LIQUIDE BELGE S.A./N.V.
national supplier
Avenue de Bourget / Bourgetlaan 44, 1130 Bruxelles-Brussel, Belgium
L'AIR LIQUIDE LUXEMBOURG S.A.
national supplier
ZONE P.E.D.-B.P.20, L-4801 RODANGE, Luxemburg
https://www.airliquide-benelux.com
AIR LIQUIDE BeNeLux
manufacturer
Avenue de Bourget / Bourgetlaan 1130 Brussel Belgium
0032 (0) 2 431 72 00
Emergency Contacts
Emergency Contact
+31 (0)40 250 35 03
Emergency Contact
+32 (0)2 431 72 00
Emergency Contact
+352 50 62 63 1
Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid
+32 70 245 245
Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid
02 264 96 30
Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid
+352 8002 5500
FR, DE
Nationaal Vergiftigingen Informatie Centrum
+31 88 755 80 00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Adverse effects not expected from this product.
Adverse effects not expected from this product.
Adverse effects not expected from this product.
Ingestion is not considered a potential route of exposure.
Immediate Medical Attention
None.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray or fog. Product does not burn, use fire control measures appropriate for the surrounding fire.
Do not use water jet to extinguish.
Supports combustion. Exposure to fire may cause containers to rupture/explode.
Use fire control measures appropriate for the surrounding fire. Cool endangered receptacles with water spray jet from a protected position. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. Move containers away from the fire area if this can be done without risk.
Firefighter Protection
Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire fighters. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Standard EN 469 - Protective clothing for firefighters. Standard - EN 659: Protective gloves for firefighters.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Act in accordance with local emergency plan.
None.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe gas. The product must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularly) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Contact your gas supplier if in doubt. Use only oxygen approved lubricants and oxygen approved sealings. Avoid suck back of water, acid and alkalis. Refer to supplier's container handling instructions. Do not allow backfeed into the container. Protect containers from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Leave valve protection caps in place until the container has been secured against either a wall or bench or placed in a container stand and is ready for use. If user experiences any difficulty operating valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty, even if still connected to equipment. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels provided by the supplier for the identification of the content of the container. Suck back of water into the container must be prevented. Open valve slowly to avoid pressure shock.
Containers should be stored in the vertical position and properly secured to prevent them from falling over. Containers should not be stored in conditions likely to encourage corrosion.
The product must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product.
Do not smoke while handling product. Never use direct flame or electrical heating devices to raise the pressure of a container.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularly checked for leakages. Consider the use of a work permit system e.g. for maintenance activities.
Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk, performance level 1 or higher.
Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications.
Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD. Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems.
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
None in addition to the above sections.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazard other than the effects described in sub-sections below. Data for mixture are not available.
None.
Avoid moisture in installation systems.
For additional information on compatibility refer to ISO 11114.
None.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1002
- Shipping Name
- AIR, COMPRESSED
- Transport Class
- 2.2
- Packing Group
- Not established.
P200. Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: Ensure there is adequate ventilation. Ensure that containers are firmly secured. Ensure valve is closed and not leaking. Ensure valve outlet cap nut or plug (where provided) is correctly fitted. Ensure valve protection device (where provided) is correctly fitted.
P200
200
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Compressed air?
The signal word is warning.
What is the physical form of Compressed air?
Compressed air is a gas with mixture contains one or more component(s) which have the following colour(s): colourless. color. It has odourless. odour threshold is subjective and inadequate to warn of overexposure. odor.
What is Compressed air used for?
Industrial and professional uses. Perform risk assessment prior to use. Test gas/Calibration gas. Purge gas, diluting gas, inerting gas. Consumer use. Perform risk assessment prior to use. Breathing gas. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.
What are the hazard statements for Compressed air?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Compressed air?
The melting point is Not known. and the boiling point is Not known..