NextSDS Logo
Safety Data Sheet EN

AIR, COMPRESSED

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AIR, COMPRESSED
Product Code
LIND-P002
Synonyms
Compressed Oxygen and Nitrogen mixture; Synthetic air; Reconstituted air; Medical air; Medical air, USP, Grade 0.1, Air Zero Emission Bar 97, Zero 2, Extra Dry, Air Diving Grade

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial and professional use. Medical. Calibration/test gas.

Uses advised against

Consumer use

Manufacturers & Suppliers

Messer North America, Inc. - Messer LLC - Messer Merchant Production LLC logo

Messer North America, Inc. - Messer LLC - Messer Merchant Production LLC

manufacturer

200 Somerset Corporate Blvd, Suite 7000, Bridgewater, NJ 08807

908-464-8100

http://www.messer-us.com

M

Messer Gas Puerto Rico, Inc.

manufacturer

Road 869, Km 1.8, Barrio Palmas, Catano, PR 00962

787-641-7445

Emergency Contacts

Messer National Operations Center, US

+1 800-232-4726

CHEMTREC

1-800-424-9300

CHEMTREC

+1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Gases under pressure

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated
H290 Supports combustion

Precautionary Statements

P202 Do not handle until all safety precautions have been read and understood
P243 Protect from sunlight when ambient temperature exceeds 52°C/125°F
P244 Close valve after each use and when empty
P271 Use a backflow preventive device in piping
Use and store only outdoors or in a well ventilated place
Use only with equipment rated for cylinder pressure

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
AIR 132259-10-0 99% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

None under normal use.

Skin contact

None under normal use.

Eye contact

None under normal use.

Ingestion

None under normal use.

Medical Treatment

Not available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

None.

Specific hazards

Non-flammable gas. Cylinders may rupture under extreme heat.

Instructions

Continue to cool fire exposed cylinders until flames are extinguished. Damaged cylinders should be handled only by specialists.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Ensure adequate ventilation, especially in confined areas. Monitor oxygen level. Wear self-contained breathing apparatus when entering area unless atmosphere is proved to be safe.

Environmental

Prevent spreading of vapors through sewers, ventilation systems and confined areas.

Cleanup methods

Return cylinder to Messer or an authorized distributor.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Protect cylinders from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distance, use a cart designed to transport cylinders. Never attempt to lift a cylinder by its valve protection cap. Never insert an object (e.g. wrench, screwdriver, pry bar,etc.) into valve cap openings. Use an adjustable strap wrench to remove over-tight or rusted caps. Use only with adequate ventilation. Use a backflow preventive device in piping. Use only with equipment rated for cylinder pressure. Close valve after each use and when empty. If user experiences any difficulty operating cylinder valve discontinue use and contact supplier. Ensure the complete gas system has been checked for leaks before use. Never put cylinders into trunks of cars or unventilated areas of passenger vehicles. Never attempt to refill a compressed gas cylinder without the owner's written consent. Never strike an arc on a compressed gas cylinder or make a cylinder a part of an electrical circuit. Only experienced and properly instructed persons should handle gases under pressure.

Storage

Store in cool, dry, well-ventilated area of non-combustible construction away from heavily trafficked areas and emergency exits. Keep at temperatures below 52°C / 125°F. Cylinders should be stored upright with valve protection cap in place and firmly secured to prevent falling. Use a 'first in-first out' inventory system to prevent full cylinders from being stored for excessive periods of time. Full and empty cylinders should be segregated. Stored containers should be periodically checked for general condition and leakage.

Fire prevention

Never strike an arc on a compressed gas cylinder or make a cylinder a part of an electrical circuit.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

None under normal use conditions. Systems under pressure should be regularly checked for leakages.

Hands

Work gloves are recommended when handling cylinders.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

No special protective equipment required.

Skin/Body

Safety shoes are recommended when handling cylinders.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility
---
Flash Point
Not applicable
Properties Status
---
State Under Standard Conditions
---
Colour Intensity
---
Relative Density
---
Explosive Limits
---
Density
1.204 kg/m³@20°C
Relative Evaporation Rate
---
Form
---
Flammability
Non-flammable gas
Solubility In Fat
---
Solidification Point
---
Dynamic Viscosity
---
Partition Coefficient
Not available
Solubility In Water
Slightly soluble
Freezing Point
---
Vapor Pressure
Above critical temperature
Lower Explosive Limit
Not applicable
Ph
Not applicable
Odor
Odorless
Evaporation Rate
Not applicable
Molecular Weight
28.975
Voc Content
---
Physical State Data
gas
Colour
Colorless
Vapor Density
1
Decomposition Temperature
Not available
Metal Corrosion
---
Softening Point
---
Cloud Point
---
Appearance
Colorless
Melting Point
Not applicable
Physical State
Gas
Odor Threshold
Not available
Auto Ignition Temperature
Not available
Kinematic Viscosity
Not applicable
Upper Explosive Limit
Not applicable
Bulk Density
---
Boiling Point
-194 °C / -317 °F
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Not reactive under normal conditions

Hazardous reactions

None under normal processing.

Avoid

None known.

Incompatible

None known.

Decomposition

None known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1002
Shipping Name
Air, compressed
Transport Class
2.2
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is AIR, COMPRESSED known by?

AIR, COMPRESSED is also known as: Compressed Oxygen and Nitrogen mixture; Synthetic air; Reconstituted air; Medical air; Medical air, USP, Grade 0.1, Air Zero Emission Bar 97, Zero 2, Extra Dry, Air Diving Grade

What is the hazard signal word for AIR, COMPRESSED?

The signal word is warning.

What is the physical form of AIR, COMPRESSED?

AIR, COMPRESSED is a gas appearing as colorless with colorless color. It has odorless odor.

What is AIR, COMPRESSED used for?

Industrial and professional use. Medical. Calibration/test gas.

What are the hazard statements for AIR, COMPRESSED?

This substance has 2 hazard statements:

  • H280: Contains gas under pressure; may explode if heated
  • H290: Supports combustion

What is the melting point of AIR, COMPRESSED?

The melting point is Not applicable and the boiling point is -194 °C / -317 °F.