NextSDS Logo
Safety Data Sheet EN

C9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
C9
Product Form
Liquid.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For professional use only. Alkaline spray cleaner.

Manufacturers & Suppliers

E

Ecover Belgium NV

manufacturer

Industrieweg 3, 2390 Malle Belgium

+32 (0)3 309 25 00

Emergency Contacts

Antipoison Centre Belgium

+32 (0)70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flammable.

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H226 Flammable.
H242 Above 37°C explosive vapour/air mixtures may be formed.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This product contains hazardous components (Directive 67/548/EEC). Regulation (CE) No. 648/2004 of 31 March 2004 on detergents: < 5% : - Nonionic surfactants

Chemical Name CAS Number Concentration Hazardous
Ethanol EC: 200-578-6 64-17-5 10 - 100% Yes
Sodium octyl sulfate EC: 205-535-5 142-31-4 1 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Rest. Assure fresh air breathing.

Skin contact

Rinse affected area thoroughly with water to remove concentrated product. Remove contaminated clothing.

Eye contact

Rinse immediately with plenty of water. Seek medical attention if irritation develops.

Ingestion

In case of ingestion of large quantities, let the victim drink plenty of water and seek medical attention. Do not induce vomiting!

Medical Treatment

No specific recommendations.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishing media can be used. Alcoholresistant foam.

Unsuitable media

Do not use a heavy water stream.

Instructions

Exercise caution when fighting any chemical fire. Cool heat-exposed product with water spray.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Avoid release to the environment.

Cleanup methods

Collect leakage in non-lockable container. Absorb spillage with sand or inert material and transfer to a safe area and dispose of as chemical waste. If desired rinse remainder with water.

Materials: sand or inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from sources of ignition - No smoking.

Storage

Store in a cool, well ventilated and fireproof area, in tightly closed original packaging.

Fire prevention

Keep away from sparks, open fire and oxidising agents.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear waterproof gloves when taking up intensively material which is accidentally released. Persons with a sensitive skin are also recommended to wear waterproof gloves.

Eyes

Wear safety goggles when clearing accidentally released material and if there is a risk of splashing.

Respiratory

No specific recommendations.

Environmental

Environment protection see § 6

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Slightly yellow
Colour Intensity
---
Form
---
Odor
Odourless
Odor Threshold
---
Ph
9,75
Melting Point
---
Boiling Point
---
Flash Point
37 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,976 kg/l
Flammability
---
Upper Explosive Limit
19 vol %
Lower Explosive Limit
3.4 vol %
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Complete
Solubility In Fat
---
Molecular Weight
---
Voc Content
16.3
Metal Corrosion
---
Dynamic Viscosity
33 cP
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition under normal conditions of storage and use.

Reactivity

May form flammable/explosive vapour-air mixture.

Hazardous reactions

Reacts violently with strong oxidising agents, causing fire and explosion hazard.

Avoid

Do not store <0°C and >25°C.

Incompatible

strong oxidising agents

Decomposition

None under normal conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for C9?

The signal word is danger.

What is the physical form of C9?

C9 is a liquid with slightly yellow color. It has odourless odor.

What is C9 used for?

For professional use only. Alkaline spray cleaner.

What are the hazard statements for C9?

This substance has 2 hazard statements:

  • H226: Flammable.
  • H242: Above 37°C explosive vapour/air mixtures may be formed.