01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
C6
Product Form
Liquid.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For professional use only.

Manufacturers & Suppliers

E

Ecover Belgium NV

manufacturer

Industrieweg 3 2390 Malle Belgium

+32 (0)3 309 25 00

Emergency Contacts

Antipoison Centre Belgium

+32 (0)70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This product is not hazardous but contains hazardous components.

Chemical Name CAS Number Concentration Hazardous
Fatty Alcohol Sulfate C10-16 EC: 271-557-7 68585-47-7 10% Yes
Alkyl Poly Glycoside C10-16 110615-47-9 1 - 10% Yes
Alkyl Poly Glycoside C8-10 68515-73-1 1 - 10% Yes

AQUA, SODIUM LAURYL SULPHATE, LAURYL GLUCOSIDE, SODIUM CHLORIDE, CAPRYL GLUCOSIDE, SODIUM N- LAUROYLSARCOSINATE, COCO-GLUCOSIDE, CITRIC ACID, ALOE BARBADENSIS GEL, 2-BROMO-2-NITROPROPANE-1,3-DIOL.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Not relevant.

Skin contact

Not expected to require first aid measures.

Eye contact

Rinse immediately and for a long time with plenty of water. Seek medical attention if the irritation persists.

Ingestion

Wash out mouth and do not induce vomiting. Seek medical attention.

Immediate Medical Attention

Seek medical attention if the irritation persists. Seek medical attention.

Medical Treatment

No specific recommendations.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishing media can be used.

Unsuitable media

None.

Specific hazards

None.

Firefighter Protection

Exercise caution when fighting any chemical fire. See Heading 8.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Spill area may be slippery. Avoid contact with eyes. Equip cleanup crew with proper protection. See Heading 8.

Environmental

Avoid release to the environment.

Cleanup methods

Recover usable material in a clean closable container for reuse. Sweep up contaminated material and dispose of as chemical waste. Remove the remainder with water.

Materials: clean closable container

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes.

Storage

Store in a cool and frost-free place in a closed packaging.

Fire prevention

Not expected to be a fire/explosion hazard under normal conditions of use.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear waterproof gloves when taking up intensively material which is accidentally released.

Eyes

Wear safety goggles when clearing accidentally released material.

Respiratory

Not relevant.

Environmental

Environment protection see § 6

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Viscous liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
White/Yellow.
Colour Intensity
---
Form
---
Odor
Odourless.
Odor Threshold
---
Ph
6
Melting Point
---
Boiling Point
---
Flash Point
> 100 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,040 kg/l
Flammability
---
Upper Explosive Limit
None.
Lower Explosive Limit
None.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Complete.
Solubility In Fat
---
Molecular Weight
---
Voc Content
0
Metal Corrosion
---
Dynamic Viscosity
6500 mPa.s
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition under normal conditions of storage and use.

Avoid

Do not store <0°C and >40°C.

Decomposition

None under normal conditions.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

EC50 72h Algae (Selenastrum capricornutum) [ppm] (OECD 201) : 73 Slightly toxic 48 Hour EC50 Daphnia magna [ppm] (OECD 202) : 62 Slightly toxic Rotifer toxicity (Brachionus calyciflorus) EC50 24h (ppm) (ASTM E1440-91) : > 100 Hardly toxic.

12.2 Persistence and degradability

Biodegradation [%] Sapromat respirometry test (OECD 301 F) : 100 Biodegradable.

12.3 Bioaccumulative potential

Remarks : EcoPro products do not contain any bioaccumulating raw materials, no perfumes and so obviously no PCM or nitromusk perfume components.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The disposal should therefore be done according to national or local waste legislation.

Disposal

Waste of this product is considered chemical waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

R Phrase(s) : None. S Phrase(s) : None.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for C6?

The signal word is no signal word.

What is the physical form of C6?

C6 is a viscous liquid with white/yellow. color. It has odourless. odor.

What is C6 used for?

For professional use only.