NextSDS Logo
Safety Data Sheet EN

Precision Plus Protein Unstained Standards

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Precision Plus Protein Unstained Standards
Product Code
1610363, 1610363S, 1610363EDU, 1610396, 10022173, 12002084, 9724468

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Uses advised against

No information available

Manufacturers & Suppliers

B

Bio-Rad Laboratories Inc.

manufacturer

1000 Alfred Nobel Drive, Hercules, CA 94547, USA

B

Bio-Rad Laboratories, Life Science Group

manufacturer

2000 Alfred Nobel Drive, Hercules, California 94547, USA

B

Bio-Rad Laboratories Ltd

national supplier

The Junction, Station Road, Watford, WD17 1ET, UK

00800 00246 723

Emergency Contacts

CHEMTREC UK

44-870-8200418

24 Hour

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation

Precautionary Statements

P264 Wash face, hands and any exposed skin thoroughly after handling
P280 Wear protective gloves, protective clothing, eye protection and face protection
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
P337 + P313 If eye irritation persists: Get medical advice/attention

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
1,2,3-Propanetriol 56-81-5 20 - 35% No
Sodium lauryl sulfate 151-21-3 1 - 2.5% No
Sodium azide EC: 247-852-1 26628-22-8 0.01 - 0.099% Yes
Hydrochloric acid EC: 231-595-7 7647-01-0 0.001 - 0.01% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Skin contact

Wash skin with soap and water. In the case of skin irritation or allergic reactions see a doctor.

Symptoms: Prolonged contact may cause redness and irritation.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Keep eye wide open while rinsing. Do not rub affected area. Get medical attention if irritation develops and persists.

Symptoms: May cause redness and tearing of the eyes.

Ingestion

Rinse mouth. Never give anything by mouth to an unconscious person. Do NOT induce vomiting. Call a doctor.

Immediate Medical Attention

Get medical attention if irritation develops and persists. In the case of skin irritation or allergic reactions see a doctor. Call a doctor.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. CAUTION: Use of water spray when fighting fire may be inefficient.

Unsuitable media

Do not scatter spilled material with high pressure water streams.

Specific hazards

No information available.

Firefighter Protection

Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin, eyes or clothing. Use personal protective equipment as required.

Environmental

See Section 12 for additional Ecological Information.

Cleanup methods

Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labelled containers. Clean contaminated surface thoroughly.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Store according to product and label instructions.

Hygiene

Avoid contact with skin, eyes or clothing. Wear suitable gloves and eye/face protection. Do not eat, drink or smoke when using this product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No information available.

Hands

Wear suitable gloves.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
---
Solidification Point
---
Ph
6.8
Relative Density
No data available
Density
No data available
Auto Ignition Temperature
248 °C
Vapor Pressure
No data available
Crystallisation Point
---
Kinematic Viscosity
No data available
Appearance
aqueous solution
Odor Threshold
No information available
Softening Point
---
Solubility In Fat
---
Melting Point
> 0 °C
Upper Explosive Limit
No data available
Colour Intensity
---
Metal Corrosion
---
Colour
blue
State Under Standard Conditions
---
Physical State
Liquid
Freezing Point
---
Flammability
No data available
Evaporation Rate
---
Decomposition Temperature
---
Properties Status
---
Molecular Weight
---
Partition Coefficient
No data available
Odor
Slight.
Solubility In Water
Miscible in water
Physical State Data
liquid
Cloud Point
---
Relative Evaporation Rate
---
Form
---
Voc Content
---
Flash Point
No data available
Bulk Density
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Boiling Point
> 100 °C
Dynamic Viscosity
No data available
Solubility
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No information available.

Hazardous reactions

Avoid contact with metals. This product contains Sodium azide. Sodium azide can react with Copper, Brass, Lead, and solder in piping systems to form explosive compounds and toxic gases.

Avoid

Avoid contact with metals.

Incompatible

Copper, Brass, Lead, and solder

Decomposition

explosive compounds and toxic gases

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Precision Plus Protein Unstained Standards?

The signal word is warning.

What is the physical form of Precision Plus Protein Unstained Standards?

Precision Plus Protein Unstained Standards is a liquid appearing as aqueous solution with blue color. It has slight. odor.

What is Precision Plus Protein Unstained Standards used for?

Laboratory chemicals

What are the hazard statements for Precision Plus Protein Unstained Standards?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation

What is the melting point of Precision Plus Protein Unstained Standards?

The melting point is > 0 °C and the boiling point is > 100 °C.