Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Precision Plus Protein Unstained Standards
- Product Code
- 1610363, 1610363S, 1610363EDU, 1610396, 10022173, 12002084, 9724468
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Uses advised against
No information available
Manufacturers & Suppliers
Bio-Rad Laboratories Inc.
manufacturer
1000 Alfred Nobel Drive, Hercules, CA 94547, USA
Bio-Rad Laboratories, Life Science Group
manufacturer
2000 Alfred Nobel Drive, Hercules, California 94547, USA
Bio-Rad Laboratories Ltd
national supplier
The Junction, Station Road, Watford, WD17 1ET, UK
00800 00246 723
Emergency Contacts
CHEMTREC UK
44-870-8200418
24 Hour
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,2,3-Propanetriol | 56-81-5 | 20 - 35% | No |
| Sodium lauryl sulfate | 151-21-3 | 1 - 2.5% | No |
| Sodium azide EC: 247-852-1 | 26628-22-8 | 0.01 - 0.099% | Yes |
| Hydrochloric acid EC: 231-595-7 | 7647-01-0 | 0.001 - 0.01% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air.
Wash skin with soap and water. In the case of skin irritation or allergic reactions see a doctor.
Symptoms: Prolonged contact may cause redness and irritation.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Keep eye wide open while rinsing. Do not rub affected area. Get medical attention if irritation develops and persists.
Symptoms: May cause redness and tearing of the eyes.
Rinse mouth. Never give anything by mouth to an unconscious person. Do NOT induce vomiting. Call a doctor.
Immediate Medical Attention
Get medical attention if irritation develops and persists. In the case of skin irritation or allergic reactions see a doctor. Call a doctor.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. CAUTION: Use of water spray when fighting fire may be inefficient.
Do not scatter spilled material with high pressure water streams.
No information available.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes or clothing. Use personal protective equipment as required.
See Section 12 for additional Ecological Information.
Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labelled containers. Clean contaminated surface thoroughly.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Prolex™ Staph Positive Control Reagent
---
AlphaPlus® C14-16-18
CAS: 1120-36-1, 629-73-2, 112-88-9
Pierce Abundent Protein Depletion Spin Columns
---
Sil-Select Plus
---
BenchMark Special Stains Deparaffinization Solution (10X)
---
LPS® Precision Clean (Concentrate)
---
Staphaurex Plus 450 tests
---
AlphaPlus® C20-24
CAS: 93924-10-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product.
Keep containers tightly closed in a dry, cool and well-ventilated place. Store according to product and label instructions.
Avoid contact with skin, eyes or clothing. Wear suitable gloves and eye/face protection. Do not eat, drink or smoke when using this product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No information available.
Wear suitable gloves.
Wear safety glasses with side shields (or goggles).
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.
Wear suitable protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No information available.
Avoid contact with metals. This product contains Sodium azide. Sodium azide can react with Copper, Brass, Lead, and solder in piping systems to form explosive compounds and toxic gases.
Avoid contact with metals.
Copper, Brass, Lead, and solder
explosive compounds and toxic gases
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Precision Plus Protein Unstained Standards?
The signal word is warning.
What is the physical form of Precision Plus Protein Unstained Standards?
Precision Plus Protein Unstained Standards is a liquid appearing as aqueous solution with blue color. It has slight. odor.
What is Precision Plus Protein Unstained Standards used for?
Laboratory chemicals
What are the hazard statements for Precision Plus Protein Unstained Standards?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation
What is the melting point of Precision Plus Protein Unstained Standards?
The melting point is > 0 °C and the boiling point is > 100 °C.